Maintenance and Care

Trigno sensors are encased in a sealed polycarbonate enclosure. 

The following points should be kept in mind when handling the 

sensors.

• 

All sensors should be visually inspected before each use to en-

sure that no mechanical deterioration has occurred. 

• 

The sensors can be cleaned with 70% isopropyl alcohol swabs. 

Ensure that the sensor contacts remain clean at all times for 

proper operation.

• 

The sensors are not waterproof and should not be submerged 

in any liquids under any circumstance.  The ingress of liquids 

may compromise the safety features of the device. These devic-

es are not intended for use under high-sweat conditions, where 

the accumulation or the entrapment of sweat can expose the 

sensor to sustained levels of dampness.

• 

The sensor contacts are made of pure silver and are quite soft. 

Care should be taken to preserve the integrity of these con-

tacts. Do not scrape or dent these contacts.

• 

Handle the sensors with care: do not drop them on the ground 

or step on them.

• 

The cable connecting the MiniHead sensing element to the 

sensor body is designed to be supple and unobtrusive while 

being worn.  Take care to never pull device by the cable, or 

excessively stress this cable as this may result in cable damage.  

Inspect the device prior to each use to ensure that not deterio-

ration has occurred.

• 

Battery duration is a function of battery age and charge/dis-

charge conditions. Optimal battery performance is obtained 

when the device is operated at room temperature.  Excessive 

heating (above 40 deg. C) or excessive cooling (below 5 deg. 

C) may damage the internal battery. Contact Delsys Techni-

cal support if the device is exposed to temperatures outside of 

these limits.

• 

The device battery capacity is typically expected to decrease to 

80% of it’s original capacity after 300 charge/discharge cycles. 

Содержание TRIGNO

Страница 1: ...TRIGNOTM EMG System Copyright Delsys Incorporated Delsys Logo and EMGworks are Registered Trademarks of Delsys Inc MAN 015 1 3 Spring Contact Adapter User s Guide...

Страница 2: ......

Страница 3: ...Service and Support 4 Warnings and Precautions 5 Device Information 6 Disclaimer 8 System Requirements 8 Spring Contact Adpater Overview 9 Using the Sensors 10 Charging the Sensors 10 Sensor Pairing...

Страница 4: ...the EMG and supporting signals by a qualified individual is required Rx ONLY DO NOT USE on Patients with implanted electronic devices of any kind including cardiac pace makers or similar assistive de...

Страница 5: ...sitive electronic device Avoid static discharges Do not oper ate or store near strong electrostatic electromagnetic magnetic or radioactive fields Interference from external sources may decrease the s...

Страница 6: ...cell Storing or operating the device and conse quently the cell outside of this temperature range may compro mise the integrity and the safety features of the cell Device Information Complies with Re...

Страница 7: ...ntenna type and its gain should be so chosen that the equivalent isotropi cally radiated power EIRP is not more than that required for successful communication This equipment has been tested and found...

Страница 8: ...d upon theory of warranty contract tort or otherwise No representative agent or licensed practitioner is authorized to waive this disclaimer DELSYS INC makes no diagnosis or prescription by virtue of...

Страница 9: ...er contacts to establish a local electrical reference from which to measure the EMG signals detected by the spring contacts The sensor body includes an onboard 1 5g 6g accelerometer Spring Contact Adp...

Страница 10: ...dapter for your location Ensure that the Trigno sensors are properly fitted in the recharge pockets The sensor LEDs will illuminate to amber during charging and green when charge is complete The recha...

Страница 11: ...Gworks initiate pairing by right clicking the Trigno hardware icon in the system notification area and select ing the appropriate menu item Figure 3 Invoking the Pair command Right click on the Trigno...

Страница 12: ...is being paired for the first time with the base station the choice will read Use Default Calibration rather than Use Auto detected Calibra tion Figure 5 The calibration can be auto detected or manual...

Страница 13: ...all 4 contacts are visible and one 2 slot interface to the sensor head on the opposite side of the spring contacts 1 Identify the 2 slot adhesive interfaces to be used with the spring contact sensor...

Страница 14: ...the skin Ensure that the refer ence contact location is appropriately prepared for optimal sig nal quality Adhesive Sensor Interfaces are for single use only Immediately discontinue use if skin irrit...

Страница 15: ...and are quite soft Care should be taken to preserve the integrity of these con tacts Do not scrape or dent these contacts Handle the sensors with care do not drop them on the ground or step on them Th...

Страница 16: ...he battery Periodically charge the sensors at least once every 3 months to extend battery life Do not submerge the sensors in any liquid under any cir cumstance The sensors contain sensitive electroni...

Страница 17: ...Y 6g 0 052g 0 088g Z 6g 1 Range is characterized in open office environments Interfering RF sources in the 2 4 GHz spectrum as well as absorptive objects occluding the RF communication path may degrad...

Страница 18: ...Trigno Spring Contact Adapter User s Guide 18 This page has been intentionally left blank...

Отзывы: