Connect the Front End for a Dual-Controller Storage Center
Dell Compellent
111
See Also
Connect iSCSI Servers
Choose
the
iSCSI
connectivity
option
that
best
suits
the
front
‐
end
redundancy
requirements
and
network
infrastructure.
Legacy Mode with Single-Network iSCSI
Connect
legacy
mode
iSCSI
to
a
single
network
if
only
one
Ethernet
switch
is
available
and
you
want
to
protect
against
controller
failure.
In
this
configuration,
two
fault
domains
are
spread
across
both
controllers.
Each
fault
domain
contains
sets
of
primary
and
reserve
paths
(P1
‐
R1
and
P2
‐
R2).
The
reserved
paths
provide
redundancy
for
single
controller
failure.
This
configuration
is
vulnerable
to
switch
failure.
Prerequisites
Each
controller
must
have
two
available
iSCSI
front
‐
end
ports.
Steps
1
Connect
each
iSCSI
server
to
both
Ethernet
switches.
2
Connect
fault
domain
1
(shown
in
orange)
to
switch
1.
Primary
port
P1
:
Controller
A,
slot
3,
port
1
→
Switch
1
Reserved
port
R1
:
Controller
B,
slot
3,
port
1
→
Switch
1
3
Connect
fault
domain
2
(shown
in
blue)
to
switch
1.
Primary
port
P2
:
Controller
B,
slot
4,
port
2
→
Switch
1
Reserved
port
R2
:
Controller
A,
slot
4,
port
2
→
Switch
1
Note:
To
prevent
a
port
or
cable
failure
from
blocking
access
to
volumes
mapped
to
a
controller,
connect
two
additional
fault
domains
so
that
each
controller
has
two
primary
paths
to
the
iSCSI
network.
Содержание SC8000
Страница 1: ...Dell Compellent Storage Center SC8000 Controller Deployment Guide ...
Страница 64: ...Chapter 2 Install the Hardware 54 Storage Center SC8000 Controller Deployment Guide ...
Страница 163: ...Complete the Startup Wizard Dell Compellent 153 6 Click Continue The Generate SSL Cert page appears ...
Страница 217: ......
Страница 218: ...680 087 001 D ...