Verify Connectivity and Failover
Dell Compellent
167
d
After
the
copy
finishes,
turn
on
the
controller.
e
Wait
3
minutes
and
verify
that
the
controller
has
finished
starting.
f
Rebalance
the
ports.
3
Manually
shut
down
the
second
controller
while
copying
data
to
TestVol2
to
verify
that
IO
is
not
interrupted
by
the
failover
event.
a
Copy
the
Test
folder
to
the
TestVol2
volume.
b
During
the
copy
process,
shut
down
the
second
controller
(the
controller
through
which
the
volume
is
mapped).
c
Verify
that
the
copy
process
continues
after
the
controller
is
shut
down.
d
After
the
copy
finishes,
turn
on
the
controller.
e
Wait
3
minutes
and
verify
that
the
controller
has
finished
starting.
f
Rebalance
the
ports.
Test MPIO
If
the
network
environment
and
servers
are
configured
for
MPIO,
perform
tests
to
make
sure
that
failed
paths
do
not
interrupt
IO.
1
Create
a
Test
folder
on
the
server
and
copy
at
least
2GB
of
data
into
it.
2
Make
sure
that
the
FC
or
iSCSI
server
is
configured
to
use
load
balancing
MPIO
(round
‐
robin).
3
Manually
disconnect
a
path
while
copying
data
to
TestVol1
to
verify
that
MPIO
is
functioning
correctly.
a
Copy
the
Test
folder
to
the
TestVol1
volume.
b
During
the
copy
process,
disconnect
one
of
the
paths
and
verify
that
the
copy
process
continues.
c
Reconnect
the
port.
4
Repeat
as
necessary
to
test
additional
paths.
5
(Dual
‐
controller
Storage
Center)
Restart
the
controller
that
contains
the
active
path
while
IO
is
being
transferred.
6
If
the
Storage
Center
is
not
in
a
production
environment,
restart
the
switch
that
contains
the
active
path
while
IO
is
being
transferred.
Clean up Test Volumes
After
testing
is
complete,
delete
the
volumes
used
for
testing.
Содержание SC8000
Страница 1: ...Dell Compellent Storage Center SC8000 Controller Deployment Guide ...
Страница 64: ...Chapter 2 Install the Hardware 54 Storage Center SC8000 Controller Deployment Guide ...
Страница 163: ...Complete the Startup Wizard Dell Compellent 153 6 Click Continue The Generate SSL Cert page appears ...
Страница 217: ......
Страница 218: ...680 087 001 D ...