![Dell SC8000 Скачать руководство пользователя страница 203](http://html.mh-extra.com/html/dell/sc8000/sc8000_deployment-manual_79830203.webp)
Removing Enclosures
Dell Compellent
193
Removing Enclosures
The
following
procedure
describes
how
to
use
Storage
Center
System
Manager
to
move
data
off
the
disks
in
the
enclosure
to
be
removed.
For
more
detailed
instructions,
see
the
Storage
Center
System
Manager
Administrator’s
Guide
.
Release Disks
Release
disks
to
remove
them
from
the
pool
in
preparation
of
removing
the
enclosure.
1
In
the
Storage
Center
tree,
expand
the
Disks
node
to
view
the
disks
in
the
enclosure.
2
Select
all
the
disks
in
the
enclosure
you
are
removing.
3
From
the
shortcut
menu,
select
Release
Disk
.
The
Release
Disk
wizard
starts.
4
Note
the
warning
and
click
Yes
to
continue.
The
disk
is
immediately
released
and
a
dialog
box
opens
asking
if
you
wish
to
rebalance
RAID
devices
now,
later,
or
skip
balancing.
5
Click
Yes
.
Wait
for
the
rebalance
operation
to
finish.
Enclosures
with
all
drives
in
the
unassigned
disk
folder
are
now
safe
to
remove.
Remove an SC280 Enclosure
These
instructions
describe
how
to
remove
an
enclosure
from
an
SC280
enclosure
chain.
If
the
configuration
has
two
enclosure
chains,
you
do
not
need
to
take
a
system
outage;
however,
the
controller
must
be
able
to
see
all
drives
through
one
chain
while
the
other
side
is
down.
Disconnect the A-side Chain
Disconnect
the
enclosure
to
be
removed
from
the
A
‐
side
chain.
1
Disconnect
the
A
‐
side
cable
from
Controller
B:
slot
3,
port
3.
The
B
side
continues
to
carry
IO
while
the
A
side
is
disconnected
(see
2
In
the
Storage
Center
System
Manager,
select
Storage
Management
→
System
→
Setup
→
Configure
Local
Ports
.
3
Make
sure
that:
Slot
and
slot
ports
are
Up
and
the
Purpose
is
set
to
back
‐
end
.
Target
Count
equals
the
number
of
added
drives,
demonstrating
that
the
controller
recognizes
the
new
enclosures.
4
Remove
the
cable
between:
Enclosure
1:
left,
port
B
→
Enclosure
2:
left,
port
A
(see
5
Move
the
cable
from
Enclosure
2:
left,
port
C
→
Enclosure
1:
left,
port A
(see
6
Reconnect
the
top
cable
to
Controller
B:
slot
3,
port
3
(see
).
Caution:
Before
you
remove
an
enclosure,
make
sure
that
your
data
is
backed
up
and
that
all
disks
to
be
removed
are
empty
of
data.
Caution:
To
disconnect
the
A
‐
side
cabling
without
a
system
outage,
make
sure
that
you
first
disconnect
the
A
‐
side
cable
from
the
controller.
Disconnecting
any
other
cable
first
disrupts
IO
to
the
enclosure,
resulting
in
a
system
outage.
Содержание SC8000
Страница 1: ...Dell Compellent Storage Center SC8000 Controller Deployment Guide ...
Страница 64: ...Chapter 2 Install the Hardware 54 Storage Center SC8000 Controller Deployment Guide ...
Страница 163: ...Complete the Startup Wizard Dell Compellent 153 6 Click Continue The Generate SSL Cert page appears ...
Страница 217: ......
Страница 218: ...680 087 001 D ...