Chapter 4 Connect the Front End
114
Storage Center SC8000 Controller Deployment Guide
Virtual Port Mode with Single-Network iSCSI
Connect
virtual
port
mode
iSCSI
to
a
single
network
if
only
one
Ethernet
switch
is
available
and
you
want
to
protect
against
port
or
controller
failure.
In
this
configuration,
there
is
one
fault
domain
because
there
is
a
single
network.
Each
controller
is
connected
to
the
fabric
by
at
least
two
iSCSI
connections
to
provide
port
redundancy.
If
a
single
port
fails,
its
virtual
port
fails
over
to
another
port.
If
a
controller
fails,
the
virtual
ports
on
the
failed
controller
move
to
ports
on
the
other
controller.
This
configuration
is
vulnerable
to
switch
failure.
Prerequisites
Each
controller
must
have
two
available
iSCSI
front
‐
end
ports.
The
requirements
for
virtual
port
mode
must
be
met.
Steps
1
Connect
each
server
to
the
iSCSI
network.
2
Connect
fault
domain
1
(shown
in
orange)
to
iSCSI
network
1.
Controller
A,
slot
3,
port
1
→
Switch
1
Controller
B,
slot
3,
port
1
→
Switch
1
Controller
B,
slot
4,
port
2
→
Switch
1
Controller
A,
slot
4,
port
2
→
Switch
1
Figure 98. Dual-Controller with Single-Network iSCSI in Virtual Port Mode
Ethernet Switch 1
iSCSI Network 1
Server
Controller B
Controller A
4
3
2 1
4
3
2 1
1 2
1 2
2 1
2 1
Содержание SC8000
Страница 1: ...Dell Compellent Storage Center SC8000 Controller Deployment Guide ...
Страница 64: ...Chapter 2 Install the Hardware 54 Storage Center SC8000 Controller Deployment Guide ...
Страница 163: ...Complete the Startup Wizard Dell Compellent 153 6 Click Continue The Generate SSL Cert page appears ...
Страница 217: ......
Страница 218: ...680 087 001 D ...