Front-End Connectivity Modes
Dell Compellent
97
Virtual Port Mode
Virtual
port
mode
provides
port
and
controller
redundancy
by
connecting
multiple
active
ports
to
each
Fibre
Channel
or
Ethernet
switch.
In
virtual
port
mode,
each
physical
port
has
a
WWN
(World
Wide
Name),
and
is
also
assigned
an
additional
virtual
WWN.
Servers
target
only
the
virtual
WWNs.
During
normal
conditions,
all
ports
process
IO.
If
a
port
or
controller
fails,
a
virtual
WWN
can
be
moved
to
another
physical
WWN
in
the
same
fault
domain.
When
the
failure
is
resolved
and
ports
are
rebalanced,
the
virtual
port
returns
to
the
preferred
physical
port.
Virtual
port
mode
provides
the
following
advantages
over
legacy
mode:
Increased
performance
:
Because
all
ports
are
active,
additional
front
‐
end
bandwidth
is
available
without
sacrificing
redundancy.
Improved
redundancy
:
Ports
can
fail
over
individually
instead
of
by
controller.
Simplified
iSCSI
configuration
:
Each
fault
domain
has
an
iSCSI
control
port
that
coordinates
discovery
of
the
iSCSI
ports
in
the
domain.
When
a
server
targets
the
iSCSI
port
IP
address,
it
automatically
discovers
all
ports
in
the
fault
domain.
Fault Domains in Virtual Port Mode
Fault
domains
group
front
‐
end
ports
that
are
connected
to
the
same
Fibre
Channel
fabric
or
Ethernet
network.
Ports
that
belong
to
the
same
fault
domain
can
fail
over
to
each
other
because
they
have
the
same
connectivity.
The
following
requirements
apply
to
fault
domains
in
virtual
port
mode:
A
separate
fault
domain
must
be
created
for
each
front
‐
end
Fibre
Channel
fabric
or
Ethernet
network.
A
fault
domain
must
contain
a
single
type
of
transport
media
(FC
or
iSCSI,
but
not
both).
Dell
Compellent
recommends
configuring
at
least
two
connections
from
each
controller
to
each
Fibre
Channel
or
Ethernet
network
(fault
domain).
Requirements for Virtual Port Mode
The
following
requirements
must
be
met
to
configure
a
Storage
Center
in
virtual
port
mode.
Note:
Dell
Compellent
strongly
recommends
using
virtual
port
mode
unless
the
network
environment
does
not
meet
the
requirements
for
virtual
port
mode.
Requirement
Description
License
The
Storage
Center
must
be
licensed
for
virtual
port
mode.
Switches
Front
‐
end
ports
must
be
connected
to
Fibre
Channel
or
Ethernet
switches;
servers
cannot
be
directly
connected
to
controller
front
‐
end
ports.
Содержание SC8000
Страница 1: ...Dell Compellent Storage Center SC8000 Controller Deployment Guide ...
Страница 64: ...Chapter 2 Install the Hardware 54 Storage Center SC8000 Controller Deployment Guide ...
Страница 163: ...Complete the Startup Wizard Dell Compellent 153 6 Click Continue The Generate SSL Cert page appears ...
Страница 217: ......
Страница 218: ...680 087 001 D ...