3–Adapter Management Applications
Configuring iSCSI over DCBX
120
CU0354602-00 L
swd77(config)
#do show lldp interface tengigabitethernet 0/16
LLDP information for Te 0/16
State: Enabled
Mode: Receive/Transmit
Advertise Transmitted: 30 seconds
Hold time for advertise: 120 seconds
Re-init Delay Timer: 2 seconds
Tx Delay Timer: 1 seconds
DCBX Version : CEE
Auto-Sense : Yes
Transmit TLVs: Chassis ID Port ID
TTL IEEE DCBx
DCBx FCoE App DCBx FCoE Logical Link
Link Prim Brocade Link DCB
x iSCSI App
DCBx FCoE Priority Bits: 0x8
DCBx iSCSI Priority Bits: 0x80
swd77(config)
#do show cee maps iscsi-dcbx
CEE Map iscsi-dcbx
Precedence 1
Priority Group Table
6: Weight 10, PFC Disabled, TrafficClass 6, BW% 10
7: Weight 90, PFC Enabled, TrafficClass 7, BW% 90
15.0: PFC Disabled
15.1: PFC Disabled
15.2: PFC Disabled
15.3: PFC Disabled
15.4: PFC Disabled
15.5: PFC Disabled
15.6: PFC Disabled
15.7: PFC Disabled
Priority Table
CoS: 0 1 2 3 4 5 6 7
---------------------------------------------
PGID: 6 6 6 6 6 6 6 7
FCoE CoS: None
Enabled on the following interfaces
Te 0/16