Planning: MD3200i Series Storage Array Terms and Concepts
39
If a disk drive rebuild fails because of a source drive failure or because the
drive is too small, the MDSM reports a failure of the physical disk even
though the LED state on the drive indicates the rebuild was aborted (green
for 3 seconds, amber for 3 seconds, then off for 3 seconds).
Self-Monitoring Analysis and Reporting Technology
SMART monitors the internal performance of all physical disk components to
detect faults indicating the potential for physical disk failure. SMART uses
this information to report whether failure is imminent so that a physical disk
can be replaced before failure occurs. The storage array monitors all attached
drives and notifies you when a predicted failure is reported by a physical disk.
Virtual Disks and Disk Groups
When configuring a storage array, you must:
1
Organize the physical disks into disk groups.
2
Create virtual disks within these disk groups.
3
Provide host server access.
4
Create mappings to associate the virtual disks with the host servers.
NOTE:
Host server access must be created before mapping virtual disks.
Offline
Not applicable The physical disk has either been spun
down or had a rebuild aborted by user
request.
Green flashing
(3000 ms), Amber
(3000 ms), and
Off (3000 ms)
Identify
Assigned,
Unassigned,
Hot Spare in
use, or Hot
Spare standby
The physical disk is being identified. Green flashing
(250 ms)
N/A
N/A
The indicated slot is empty, or the
array cannot detect the physical disk.
Table 4-1. RAID Controller Physical Disk States
(continued)
Status
Mode
Description
Physical Disk
Status LED
book.book Page 39 Saturday, September 24, 2011 9:06 AM
Содержание PowerVault MD3200i Series
Страница 18: ...18 Contents ...
Страница 22: ...22 Introduction ...
Страница 60: ...60 Planning MD3200i Series Storage Array Terms and Concepts ...
Страница 148: ...148 Configuration Disk Groups and Virtual Disks ...
Страница 172: ...172 Configuration Premium Feature Snapshot Virtual Disks ...
Страница 188: ...188 Configuration Premium Feature Upgrading to High Performance Tier ...
Страница 200: ...200 Configuration Device Mapper Multipath for Linux ...
Страница 236: ...236 Management Firmware Inventory ...
Страница 262: ...262 Troubleshooting Your Storage Array Software ...
Страница 274: ...274 Getting Help ...
Страница 282: ...282 Index ...