Planning: About Your Storage Array
29
Power Supply and Cooling Fan Features
The MD3200i Series storage array includes two integrated, hot-swappable
power supply/cooling fan modules. Both modules must be installed to ensure
proper cooling. The system requires at least one of the cooling fans to
function to avoid overheating.
A power supply/cooling fan module can be replaced without powering down
the system. For information on removing and installing the modules, see
"Power Supply/Cooling Fan Module" on page 225.
CAUTION:
A power supply/cooling fan module can be removed from a powered-
on system for a maximum period of 5 minutes. Beyond that time, the system may
automatically shut down to prevent damage.
Drive-Status Indicator Pattern
Condition
Off
The physical disk is:
• not yet discovered by the host server
• is spun down for removal
• not supported for the RAID controller
module or is not in the physical disk slot
NOTE:
The drive status indicator remains
off until all hard drives are initialized after
system power is turned on. Drives are not
ready for insertion or removal during this
time.
Steady green
Physical disk is online
Green flashing (On 250 ms, Off 250 ms) Physical disk is being identified
Green flashing (On 400 ms, Off 100 ms) Physical disk rebuilding
Amber flashing (On 150 ms, Off 150 ms) Physical disk failed
Flashing green, amber, and off (green On
500 ms, amber On 500 ms, Off 1000 ms)
Physical disk failure predicted (SMART)
Flashing green, amber, and Off (green 3
seconds, amber 3 seconds, and Off 3
seconds)
Physical disk rebuild aborted
book.book Page 29 Saturday, September 24, 2011 9:06 AM
Содержание PowerVault MD3200i Series
Страница 18: ...18 Contents ...
Страница 22: ...22 Introduction ...
Страница 60: ...60 Planning MD3200i Series Storage Array Terms and Concepts ...
Страница 148: ...148 Configuration Disk Groups and Virtual Disks ...
Страница 172: ...172 Configuration Premium Feature Snapshot Virtual Disks ...
Страница 188: ...188 Configuration Premium Feature Upgrading to High Performance Tier ...
Страница 200: ...200 Configuration Device Mapper Multipath for Linux ...
Страница 236: ...236 Management Firmware Inventory ...
Страница 262: ...262 Troubleshooting Your Storage Array Software ...
Страница 274: ...274 Getting Help ...
Страница 282: ...282 Index ...