252
Troubleshooting: Your Storage Array Software
• ping <host-name>
• ping <RAID controller module-IP-address>
7
If the verification is successful, see step 8, if not, see step 9.
8
Remove the storage array with the Unresponsive status from the EMW,
and select
Add Storage Array
to add the storage array again.
9
If the storage array does not return to Optimal status, check the Ethernet
cables to make sure that there is no visible damage and that they are
securely connected.
10
Make sure the appropriate network configuration tasks are performed. For
example, make sure that IP addresses are assigned to each RAID controller
module.
11
If there is a cable or network accessibility problem, see step 20, if not
step 12.
12
For an in-band managed storage array, make sure that the host is network
accessible by using the ping command to verify that the host can be
reached. Type one of these commands, and press <Enter>.
• ping <host-name>
• ping <RAID controller module-IP-address>
13
If the verification successful, see step 14, if not, step 15.
14
Remove the host with the Unresponsive status from the EMW, and select
Add Storage Array
to add the host again.
15
If the host does not return to Optimal status, go to step 16.
16
Ensure that the host is turned on and operational and that the host
adapters are installed.
17
Check all external cables and switches or hubs to make sure that no visible
damage exists and that they are securely connected.
18
Make sure the host context agent software is installed and running.
If you started the host system before you were connected to the RAID
controller module in the storage array, the host context agent software is
not able to detect the RAID controller modules. If this is the case, make
sure that the connections are secure, and restart the host context agent
software.
book.book Page 252 Saturday, September 24, 2011 9:06 AM
Содержание PowerVault MD3200i Series
Страница 18: ...18 Contents ...
Страница 22: ...22 Introduction ...
Страница 60: ...60 Planning MD3200i Series Storage Array Terms and Concepts ...
Страница 148: ...148 Configuration Disk Groups and Virtual Disks ...
Страница 172: ...172 Configuration Premium Feature Snapshot Virtual Disks ...
Страница 188: ...188 Configuration Premium Feature Upgrading to High Performance Tier ...
Страница 200: ...200 Configuration Device Mapper Multipath for Linux ...
Страница 236: ...236 Management Firmware Inventory ...
Страница 262: ...262 Troubleshooting Your Storage Array Software ...
Страница 274: ...274 Getting Help ...