System diagnostics and indicator codes
This section describes the diagnostic indicators on the system front panel that display the system status during system startup.
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Figure 66. Status LED indicators
Table 72. Status LED indicators and descriptions
Icon
Description
Condition
Corrective action
Drive indicator
The indicator turns solid amber if
there is a drive error.
●
Check the System Event Log to determine if the
drive has an error.
●
Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
●
If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
●
A cooling fan has been removed or has failed.
●
System cover, air shrouds, or back filler bracket
has been removed.
●
Ambient temperature is too high.
●
External airflow is obstructed.
If the problem persists, see
.
Electrical
indicator
The indicator turns solid amber
if the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or voltage
regulator).
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see
.
Memory indicator The indicator turns solid amber if a
memory error occurs.
Check the System Event Log or system messages
for the location of the failed memory. Reseat the
memory module.
If the problem persists, see
.
7
System diagnostics and indicator codes
77
Содержание PowerFlex R750
Страница 1: ...Dell Technologies PowerFlex Custom Node R750 Owner s Guide October 2021 Rev 01 ...
Страница 14: ...Figure 9 Service information Figure 10 Memory information and system board connectors 14 System overview ...
Страница 16: ...Figure 15 System tasks Figure 16 Heat sink Figure 17 BOSS S2 Figure 18 Express service tag 16 System overview ...