30
About Your System
E1715
Fatal I/O
Error. Review
& clear SEL.
The system BIOS has
determined there has been
a fatal error in the system.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help."
E1716
Chipset IERR
Bus
##
Dev
##
Function
##
.
Review &
clear SEL.
The system BIOS has
reported a chipset internal
error that resides in bus
##, device ##, function
##.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help."
E1717
CPU
#
internal
error. Review
& clear SEL.
The system BIOS has
determined that the
specified processor has had
an internal error.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help."
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions