30
About Your System
E1A15
SAS Cable C
SAS cable C is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 167.
E1A18
PDB Ctrl
Cable
Control cable for the power
distribution board (PDB) is
missing or bad
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 167.
E2010
No Memory
No memory is installed in
the system.
Install memory. See
"Installing Memory
Modules" on page 105.
E2011
Mem Config
Err
Memory detected, but is not
configurable. Error detected
during memory
configuration.
See "Troubleshooting
System Memory" on
page 137.
E2012
Unusable
Memory
Memory is configured, but
not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 137.
E2013
Shadow BIOS
Fail
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 137.
E2014
CMOS Fail
CMOS failure. CMOS RAM
not functioning properly.
See "Getting Help" on
page 167.
E2015
DMA
Controller
DMA controller failure.
See "Getting Help" on
page 167.
E2016
Int
Controller
Interrupt controller failure.
See "Getting Help" on
page 167.
E2017
Timer Fail
Timer refresh failure.
See "Getting Help" on
page 167.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 30 Sunday, June 21, 2009 5:16 PM
Содержание PowerEdge R300
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge R300 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents ...
Страница 46: ...46 About Your System ...
Страница 64: ...64 Using the System Setup Program ...
Страница 166: ...166 Jumpers and Connectors ...
Страница 168: ...168 Getting Help ...
Страница 186: ...186 Index W warning messages 44 warranty 11 wet system troubleshooting 132 ...