![Dell PowerEdge R300 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/dell/poweredge-r300/poweredge-r300_hardware-owners-manual_85435027.webp)
About Your System
27
E161C
PS # Input
Lost
Power source for specified
power supply is unavailable,
or out of acceptable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 135.
E1624
PS Redundancy
The power supply subsystem
is no longer redundant. If
the last supply fails, the
system will go down.
See "Troubleshooting
Power Supplies" on
page 135.
E1710
I/O Channel
Chk
The system BIOS has
reported an I/O channel
check.
See "Getting Help" on
page 167.
E1711
PCI PERR B##
D## F##
The system BIOS has
reported a PCI parity error
on a component that resides
in PCI configuration space
at bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.
PCI PERR Slot
#
The system BIOS has
reported a PCI parity error
on a component that resides
in the specified PCIe slot.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 27 Sunday, June 21, 2009 5:16 PM
Содержание PowerEdge R300
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge R300 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents ...
Страница 46: ...46 About Your System ...
Страница 64: ...64 Using the System Setup Program ...
Страница 166: ...166 Jumpers and Connectors ...
Страница 168: ...168 Getting Help ...
Страница 186: ...186 Index W warning messages 44 warranty 11 wet system troubleshooting 132 ...