![Dell PowerEdge R300 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/dell/poweredge-r300/poweredge-r300_hardware-owners-manual_85435025.webp)
About Your System
25
E1410
CPU # IERR
Specified microprocessor is
reporting an internal error.
See your system’s
"
Information Update
Tech Sheet" located on
support.dell.com
for the
most current system
information. If the
problem persists, see
"Getting Help" on
page 167.
E1414
CPU #
Thermtrip
Specified microprocessor is
out of acceptable
temperature range and has
halted operation.
See "Troubleshooting
System Cooling
Problems" on page 136. If
the problem persists,
ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 151.
NOTE:
The LCD continues
to display this message
until the system’s power
cord is disconnected and
reconnected to the AC
power source, or the SEL is
cleared using either Server
Assistant or the BMC
Management Utility. See
the
Dell
™
OpenManage
™
Baseboard Management
Controller User’s Guide
for
information about these
utilities.
E1418
CPU #
Presence
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
See "Troubleshooting the
Microprocessors" on
page 151.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 25 Sunday, June 21, 2009 5:16 PM
Содержание PowerEdge R300
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge R300 Systems Hardware Owner s Manual ...
Страница 10: ...10 Contents ...
Страница 46: ...46 About Your System ...
Страница 64: ...64 Using the System Setup Program ...
Страница 166: ...166 Jumpers and Connectors ...
Страница 168: ...168 Getting Help ...
Страница 186: ...186 Index W warning messages 44 warranty 11 wet system troubleshooting 132 ...