System diagnostics and indicator codes
This section describes the diagnostic indicators on the system front panel that displays the system status during system startup.
Topics:
•
•
System health and system ID indicator codes
•
iDRAC Quick Sync 2 indicator codes
•
iDRAC Direct LED indicator codes
•
•
•
Power supply unit indicator codes
•
•
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Figure 180. Status LED indicators
Table 46. Status LED indicators and descriptions
Icon
Description
Condition
Corrective action
Drive indicator
The indicator turns solid amber if
there is a drive error.
●
Check the System Event Log to determine if the
drive has an error.
●
Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
●
If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
●
A cooling fan has been removed or has failed.
●
System cover, air shrouds, or back filler bracket
has been removed.
●
Ambient temperature is too high.
●
External airflow is obstructed.
If the problem persists, see the
section.
Electrical
indicator
The indicator turns solid amber
if the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or voltage
regulator).
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
the PSU, check the LED on the PSU. Reseat the
PSU.
7
174
System diagnostics and indicator codes
Содержание E76S
Страница 7: ...Chapter 9 Documentation resources 186 Contents 7 ...
Страница 24: ...Figure 13 Memory information Figure 14 BOSS S2 module 24 PowerEdge T550 system overview ...
Страница 27: ...Figure 24 GPU PowerEdge T550 system overview 27 ...
Страница 73: ...Figure 66 Removing a drive bay Figure 67 Removing a drive bay Installing and removing system components 73 ...
Страница 75: ...Figure 69 Installing a drive bay Figure 70 Installing a drive bay Installing and removing system components 75 ...