Figure 31. Removing and installing the power supply blank
1.
power supply blank
2. power supply bay
Installing the power supply unit blank
Install the power supply unit blank only in the second power supply unit bay.
To install the power supply unit blank, align the blank with the power supply unit bay and push it into
the chassis until it clicks into place.
Removing an AC power supply unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
CAUTION: The system requires one power supply for normal operation. On power-redundant
systems, remove and replace only one power supply at a time in a system that is powered on.
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with
power supply removal. For information about the cable management arm, see the system’s rack
documentation.
Steps
1.
Disconnect the power cable from the power source and from the power supply unit you intend to
remove and remove the cables from the strap.
2.
Press the release latch and slide the power supply unit out of the chassis.
82