Before working inside your system
Removing the cooling shroud
Removing the internal PERC riser
Installing the cooling shroud
Installing the (optional) 2.5 inch internal hard drive carrier
After working inside your system
Installing the (optional) 2.5 inch internal hard drive carrier
Prerequisites
1
Follow the safety guidelines listed in the Safety instructions section.
2
Follow the procedure listed in the Before working inside your system section.
3
If applicable, disconnect the power or data cables from expansion card(s).
4
If required, remove the PCIe expansion card riser.
NOTE:
If applicable, close the expansion card latch on the cooling shroud to release the full length card.
5
Remove the cooling shroud.
Steps
1
Align the internal hard drive carrier with the guide pins to the slot on the internal hard drive cage.
2
Insert the internal hard drive carrier into the internal hard drive cage and press the handle-lock down to the lock position.
Installing and removing system components