temperature specification is –40°C to 65°C (–40°F to 149°F). The Maximum
temperature gradient for both operation and non-operational appliances is 20°C/h
(36°F/h).
Table 22 Temperature specifications
Temperature
Specifications
Storage
–40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than
950 m or 3117 ft)
10°C to 35°C (50°F to 95°F) with no direct
sunlight on the equipment.
Maximum temperature gradient (operating
and storage)
20°C/h (36°F/h)
For a non-operational appliance, the ambient relative humidity ranges from 5% to 95%
with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all
times. For an operational appliance, the ambient relative humidity ranges from 10% to
80% with 29°C (84.2°F) maximum dew point.
Table 23 Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum
dew point. Atmosphere must be non-
condensing at all times.
Operating
10% to 80% relative humidity with 29°C
(84.2°F) maximum dew point.
The maximum vibration specification of an operational appliance is 0.26 Grms at 5 Hz
to 350 Hz (all operation orientations).The maximum vibration specification of a non-
operational appliance is 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 24 Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.26 G
rms
at 5 Hz to 350 Hz (all operation
orientations).
Storage
1.88 G
rms
at 10 Hz to 500 Hz for 15 min (all six
sides tested).
The maximum shock specification of an operational appliance is six consecutively
executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to
2.3 ms. The maximum shock specification of a non-operational appliance is six
consecutively executed shock pulses in the positive and negative x, y, and z axes (one
pulse on each side of the appliance) of 71 G for up to 2 ms.
Table 25 Maximum shock specifications
Maximum shock
Specifications
Operating
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes of
40 G for up to 2.3 ms.
Storage
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes (one
Technical specifications
32
VxRail Appliances on 14th Generation PowerEdge
P Series, V Series, and S Series Appliance Owner's Manual