Next steps
1. Follow the procedure listed in
After working inside your system
Expansion cards
NOTE:
A missing or an unsupported expansion card riser logs an System Event Log (SEL) event. This does not prevent
your system from powering on and no BIOS, POST messages or F1 or F2 pause is displayed.
Removing the expansion card riser 1
Prerequisites
NOTE:
Install an expansion card filler bracket over an empty expansion slot to maintain Federal Communications
Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper
cooling and airflow inside the system.
1. Follow the safety guidelines listed in
.
2. Follow the procedure listed in
Before working inside your system
Steps
1. Using a Phillips #1 screw driver, remove the screws that secure the expansion card riser 1.
2. Holding the blue touch point, remove the expansion card riser from the chassis.
Figure 21. Removing the expansion card riser 1
Next steps
1.
Install the expansion card riser 1
.
46