In Linux, the file is located at: /opt/dell/ServerHardwareManager/bin.
2
Under the
[SHMSYSTEM]
section of the file, add or edit the entry
3060eLEDControl
.
•
To turn the behavior on:
3060eLEDControl=ON
.
•
To turn the behavior off:
3060eLEDControl=OFF
.
NOTE:
If the 3060eLEDControl item is missing or blank, the behavior by default is
off.
3
Save the file.
4
Restart the monitoring service.
If the LED control behavior is turned on, the following LED control will occur:
1
If a drive is reporting a predicted failure state:
a
The drive slot LED will be set to the Identify state.
b
The enclosure LED will be set to the Failure state.
2
If a drive is determined to be in a failed state:
a
The drive slot LED will be set to the Failure state.
b
The enclosure LED will be set to the Failure state.
Monitoring
45