List power supply units
Description
This command lists the power supply units (PSUs) accessible from the specified enclosure.
Command syntax
shmcli (list power supplies | listpowersupplies | lps) (-a=<(SAS WWID | AdapterIndex)> -
enc=<(WWN | EnclIndex)> [-outputformat=<SupportedOutputFormats>] | -enc=<WWN> [-
outputformat=<SupportedOutputFormats>] | [-h])
Parameters
Table 14. List power supply unit devices
Parameter
Description
-a
Specifies the adapter used for the command. This can be either SAS WWID or
AdapterIndex.
-enc
Specifies the enclosure used for the command. This is either WWN or EnclIndex.
-h
Provides more information about the command, description, and usage.
-outputformat
You can specify the following output formats: XML or JSON.
Command examples
•
list power supplies -a = 1 -enc = 500a123456789012
•
list power supplies -a = 1 -enc = 0
•
list power supplies -enc = 500a123456789012 -outputformat = xml
List temperature sensors
Description
This command lists the temperature sensors accessible from the specified enclosure.
Command syntax
shmcli (list temp sensors | listtemperaturesensors | lts) (-a=<(SAS WWID | AdapterIndex)> -
enc=<(WWN | EnclIndex)> [-outputformat<SupportedOutputFormats>] | -enc=<WWN> [-
outputformat=<SupportedOutputFormats>] | [-h])
CLI reference
29