background image

5

Versa Drawer™ Refrigeration Units 

Delfield ·  980 S. Isabella Road, Mt. Pleasant, MI 48858 ·  (989) 773-7981 or (800) 733-8829 ·  Fax (989) 773-3210 

INSTALLATION

Never stand on the unit or its drawers! Doing so may 

result in bodily injury.  

LOCATION

Units represented in this manual are intended for 

indoor use only. Be sure the location chosen has 

a floor strong enough to support the total weight of 

the cabinet and contents, which can be up to 1,200 

pounds(550kg). Reinforce the floor as necessary to 

provide for maximum loading. 
The location should be selected so that power cords 

can be connected without any extension cords.
For the most efficient operation, be sure to provide 

good air circulation inside and out. Avoid hot corners 

and locations near stoves and ovens.

Direct exposure to excessive amounts of steam in 

machine compartment will result in control board 

failure.

INSIDE CABINET

Do not pack drawer so full that air cannot circulate. 

Load product level with top of pans and keep all food 

covered.

OUTSIDE CABINET

The front louvers must be kept 24"(60cm) clear of 

any obstructions. Proper operation of these models is 

dependent on air being able to flow freely through the 

front louvers. Side louvers must have 24"(60cm) of 

clearance for service access.

Any restriction of the proper airflow outlined above, 

total or partial, will void the warranty on the unit.

LEVELING

The unit must be level so  the drain pan will drain 

properly, drawers will line up with frames and the 

cabinet will not be subject to undue strain.

STABILIZING

All models are supplied with legs or casters installed 

for your convenience, for ease of cleaning underneath. 

The unit must be installed in a stable condition.

PLUMBING

All models are standard with a condensate evaporator 

pan.

ELECTRICAL CONNECTION

 

ELECTRICAL  CONNECTIONS  AND  GROUNDING  

CONNECTIONS  MUST  COMPLY  WITH  THE  

APPLICABLE  PORTIONS  OF  THE  NATIONAL  

ELECTRICAL  CODE  AND/OR  OTHER  LOCAL  

ELECTRICAL  CODES.

 

UNITS  EQUIPPED  WITH  A  FLEXIBLE  ELECTRIC  

SUPPLY  CORD  ARE  PROVIDED  WITH  A  

THREE-PRONG  GROUNDING  PLUG.  THIS  PLUG  

MUST  BE CONNECTED  INTO  A  PROPERLY  

GROUNDED THREE-PRONG  RECEPTACLE.   IF  THE  

RECEPTACLE  IS  NOT  THE  PROPER  GROUNDING  

TYPE,  CONTACT    AN    ELECTRICIAN.    DO    NOT  

REMOVE  THE  GROUNDING  PRONG  FROM  THIS  

PLUG.

A 7' (2.1 m) long grounded supply cord with three-

pronged plug is provided with the standard units. 

Simply plug into a three-pronged wall outlet for proper 

grounding of the unit to begin operation.  
Refer to the amperage data listed in the specifications, 

the serial number tag, your local code or the National 

Electrical Code to be sure the unit is connected to the 

proper power source. A protected circuit of the correct 

voltage and amperage must be installed for connection 

of the line cord or permanent connection to the unit. 
Have the wall outlet checked by a qualified electrician 

to be sure a proper ground is present and that the 

outlet provides the correct voltage and required 

amperage to match the specifications. Do not use an 

adapter to connect to a two-pronged outlet. The three-

pronged-outlet provides a ground connection that must 

be used to prevent a shock hazard.
Any power cord that is frayed or damaged should be 

replaced. When disconnecting the unit from the power 

source, do not pull on the cord. Firmly grip the plug 

and remove from outlet.

The  unit  must  be  disconnected  from  the  power 

source whenever performing service, maintenance 

functions or cleaning the refrigerated area.

Содержание Versa Drawer 18600VD

Страница 1: ...7981 or 800 733 8829 Fax 866 779 2040 www delfield com INSTALLATION OPERATION MANUAL Versa Drawer Refrigeration Units Please read this manual completely before attempting to install or operate this eq...

Страница 2: ......

Страница 3: ...NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPTING TO CLEAN OR SERVICE DO NOT USE EXTENSION CORDS WITH THIS EQUIPMENT DO NOT...

Страница 4: ...izing 5 Plumbing 5 Electrical Connection 5 OPERATION Refrigeration System 6 Temperature Monitoring 6 Control Panel 6 Defrost 6 Operating Controls 7 MAINTENANCE General Maintenance 7 8 Stainless Steel...

Страница 5: ...ly the necessary damage forms upon request 8 Retain all crating material until an inspection has been made or waived SPECIFICATIONS 115V 60Hz NOTE This manual covers standard units only If you have a...

Страница 6: ...5 80 0cm 34 86 4cm 4 230 240 50 7 2 2 1 3 BS1373 2 850 5g 327kg F2984VDR CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 230 240 50 3 6 1 3 BS1373 850 5g 236kg F2984VDL CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 23...

Страница 7: ...aning underneath The unit must be installed in a stable condition PLUMBING All models are standard with a condensate evaporator pan ELECTRICAL CONNECTION ELECTRICAL CONNECTIONS AND GROUNDING CONNECTIO...

Страница 8: ...le without tools REFRIGERATION SYSTEM In a 4 drawer system there are two compressors one operating drawers 1 and 2 and one operating drawers 3 and 4 In a 2 drawer system there is a single compressor T...

Страница 9: ...rate freeze chill or thaw untill desired mode is reached 3 Press the drawer display button again to lock the desired mode setting NOTE Text size will return to original size Activating Manual Defrost...

Страница 10: ...ere are also stainless steel cleaners available which can restore and preserve the finish of the steels protective layer Early signs of stainless steel breakdown can consist of small pits and cracks I...

Страница 11: ...ox When finished it should be wiped clean of all food and debris Tracks The drawer box assembly must be removed Pull the drawer tracks out until they hit a stop Locate blue safety clips towards the ba...

Страница 12: ...awer Refrigeration Units Delfield 980 S Isabella Road Mt Pleasant MI 48858 989 773 7981 or 800 733 8829 Fax 989 773 3210 2 Drawer Refrigeration Schematic The four drawer unit has two of these exact sy...

Страница 13: ...P2 COND 1 COND 2 J24 J25 COMP 1 1 J11 J26 COMP 2 1 J34 J35 J36 J9 J10 BOX BOX COIL COIL 1 J30 1 J29 12 VDC SWITCH EVAP FANS DRAWER LIMIT HEATER DRAWER FRAME BOX 1 12 VDC 7 2 1 MTR MTR EVAP FANS 8 SWIT...

Страница 14: ...1 1 J23 J19 J18 50 60 HZ 85 265 VAC CONTROL POWER BOARD CONNECTOR MAP 1 J28 D3 D4 VALVES J33 J32 COND FAN 2 1 SUCTION PRESSURE TRANSDUCER J24 AC HOT 1 J26 COMP 2 1 SP2 COIL J34 2 SIGNAL 3 COMMON J11 S...

Страница 15: ...BOX J5 J7 BOX J6 D3 COIL J8 D4 COIL J10 COND 1 J9 OUT J36 OUT IN COMP 1 J11 SP1 J35 IN J34 1 SP2 J26 COMP 2 1 J24 AC HOT 24 26 J33 J25 J32 1 2 COND FAN J28 D3 D4 VALVES 1 33 25 32 14 17 18 13 12 VDC M...

Страница 16: ...TO 1 3 TO 3 2 TO 2 3 SHIELD I O TO DISP BOX 13 17 COND 2 COIL COND 1 BOX COIL J9 COIL COIL D3 BOX J5 D1 J6 BOX 1 J1 J11 J2 BOX J10 D4 J36 COIL BOX J7 D2 J8 COIL J35 J3 J4 32 MTR BLACK COM 25 WHITE VO...

Страница 17: ...ture drops into range or probe is repaired Condenser temperature probe s out of range Temperature probe to condenser is damaged or temperature is out of range Press i button to suspend audio alarm for...

Страница 18: ...ant and leak check 55 00 USD maximum reimbursement for refrigerant recovery includes recovery machine pump torch oil flux minor fittings solder brazing rod nitrogen or similar fees A maximum travel di...

Страница 19: ...TOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition does this warranty give t...

Страница 20: ...mal control adjustments or maintenance food or business loss The one year Service Labor Contract shall cover those costs incurred by the Original Purchaser for a period of one 1 year from the date of...

Страница 21: ...he parts by the original part manufacturer This Service Labor Contract is offered on all Delfield units except remote refrigerators freezers and ventilation systems installed in the United States and...

Страница 22: ...its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was...

Страница 23: ......

Страница 24: ...__________________ Installation Date _____________ For a list of Delfield s authorized parts depots visit our website at www delfield com Mt Pleasant MI Covington TN 980 S Isabella Rd Mt Pleasant MI 4...