background image

13

Versa Drawer™ Refrigeration Units 

Delfield ·  980 S. Isabella Road, Mt. Pleasant, MI 48858 ·  (989) 773-7981 or (800) 733-8829 ·  Fax (989) 773-3210 

4-Drawer Wiring Schematic

G

L1

DISPL

AY BO

ARD

SEE BO

ARD C

ONNECT

OR

FOR PIN C

ONNECTION

I/O BO

ARD

DET

AILS

I/O BOARD

2-GR

OUND

I/O BO

ARD

PO

WER T

1-+8V

N

DISP

. T

O I/O

J1

PREFER SHIELDED T

WISTED

PAIR.

 1 AND 2 T

WISTED

,

C

OMMUNIC

ATION C

ABLE

DISP

. T

O I/O

TO I/O BO

ARD

1 T

O 1

2 T

O 2

3 T

O 3

3 SHIELD

.

2 T

O 2

1 T

O 1

1

1

J2

C

ONTR

OL 

PO

WER

J18

J19

B

OX

1

J11

J1

J3

B

OX

C

OIL

J2

D1

C

OIL

J4

D2

3

6

1

J23

1

4

5
2

4

1

J22

C

OND 2

B

OX

J5

J7

B

OX

J6

D3

C

OIL

J8

D4

C

OIL

J10

C

OND 1

J9

OUT

J36

OUT

IN

C

OMP 1

J11

SP1

J35

IN

J34

1

SP2

J26

C

OMP 2

1

J24

A

C HO

T

24

26

J33

J25

J32

1

2

C

OND F

AN

J28

D3 & 

D4 V

AL

VES

1

33

25

32

14

17

18

13

12 VDC

MTR

BO

X 2

35

BO

X 1

HEA

TER

SWIT

CH

12 VDC

DR

A

WER LIMIT

EV

AP

. F

ANS

7

1

2

MTR

MTR

8

34

DR

A

WER FR

AME

PR

OBE

PR

OBE

EV

AP

. TEMP

.

BO

X TEMP

.

1

3

MTR

DR

A

WER LIMIT

DR

A

WER FR

AME

EV

AP

. TEMP

.

EV

AP

. F

ANS

12 VDC

SWIT

CH

7

MTR

9

HEA

TER

PR

OBE

PR

OBE

BO

X TEMP

.

BO

X 3

4

MTR

10
9

1

8
7

11

12

J31

1

34

J29

1

J30

36

35

37

D1 & 

D2 V

AL

VES

J27

1

11

16
12

15

DR

A

WER LIMIT

DR

A

WER FR

AME

EV

AP

. TEMP

.

12

EV

AP

. F

ANS

SWIT

CH

DR

A

WER LIMIT

5

10

11

36

HEA

TER

DR

A

WER FR

AME

EV

AP

. TEMP

.

BO

X 4

10

PR

OBE

PR

OBE

BO

X TEMP

.

6

4

EV

AP

. F

ANS

12 VDC

MTR

MTR

SWIT

CH

37

HEA

TER

BO

X TEMP

.

PR

OBE

PR

OBE

1- COMMON FOR D1 AND D2 DRW SWITCHES

6-D4 SWITCH

3-D2 SWITCH

5-D3 SWITCH

1-D3 FRAME HEATER

3-D2 FRAME HEATER

1-D1 FRAME HEATER

4- COMMON FOR D3 AND D4 DOOR SWITCHES

2-D1 SWITCH

3-D2 REFG SOLENOID

2-D1 HOT GAS SOLENOID

1-D1 REFG SOLENOID

1-D3 REFG SOLENOID

4-D2 HOT GAS SOLENOID

4-D4 HOT GAS SOLENOID

3-D4 REFG SOLENOID

2-D3 HOT GAS SOLENOID

3-D4 FRAME HEATER

SP2

J34

SOLENOID

SOLENOID

HO

T GAS

DR

A

WER ONE

SOLENOID

SOLENOID

HO

T GAS

DR

A

WER THREE

12

16

DR

A

WER T

WO

HO

T GAS

SOLENOID

SOLENOID

REFG.

 

REFG.

 

14

18

33

DR

A

WER FOUR

HO

T GAS

SOLENOID

SOLENOID

REFG.

 

C

OND

. F

AN 1

MTR

REFG.

 

PAIR. 1 AND 2 TWISTED,

PREFER SHIELDED TWISTED

11

15

1 TO 1

3 TO 3

2 TO 2

3 SHIELD.

 I/O TO DISP.

BOX

13

17

COND 2

COIL

COND 1

BOX

COIL

J9

COIL

COIL

D3

BOX

J5

D1

J6

BOX

1

J1

J11

J2

BOX

J10

D4

J36

COIL

BOX

J7

D2

J8

COIL

J35

J3

J4

32

MTR

BL

A

CK (C

OM)

25

WHITE (

V

OUT

)

RED (

VDC IN)

FOR C

OMP 1

C

OMPRESSOR 1

MTR

TR

ANSDUCER

PRESSURE

NSK

C

OND

. OUT 1

TEMP

. PR

OBE

C

OND

. IN 1

C

OND

. F

AN 2

TEMP

. PR

OBE

26

WHITE (

V

OUT

)

BL

A

CK (C

OM)

RED (

VDC IN)

MTR

C

OMPRESSOR 2

FOR C

OMP

. 2

PRESSURE

TR

ANSDUCER

NSK

TEMP

. PR

OBE

TEMP

. PR

OBE

C

OND

. OUT 2

C

OND

. IN 2

D3 & D4 VALVES

AC HOT

1

SP1

1

COMP 2

COMP 1

COND FAN

1

2

FOR ALL AC

J25-AC HOT 

J24

2- SIGNAL
3- COMMON

J11

J26

TRANSDUCER

SUCTION 
PRESSURE

1- +5V

LOADS

J32

J25

J33

D1 & D2 VALVES

1

1

J30

J28

J27

J28

J27

1

2-NC

TEMPERATURE SENSORS

COMMUNICATION CABLE

TO DISPLAY BOARD

CONTROL POWER

85-265 VAC
 50/60 HZ

BOARD CONNECTOR MAP

J19

J18

I/O TO DISP.

1

J23

1 TO 1
2 TO 2

POWER TO 

2-GROUND

DISPLAY BOARD
1-+8V

5-D3 FANS RETURN

J29

J22

6-D4 FANS RETURN

4

1

1

J31

1

2-NC

J29

1-+12V FOR D1 AND D2 FANS

4-+12V FOR D3 AND D4 FANS

2-D1 FANS RETURN
3-D2 FANS RETURN

Содержание Versa Drawer 18600VD

Страница 1: ...7981 or 800 733 8829 Fax 866 779 2040 www delfield com INSTALLATION OPERATION MANUAL Versa Drawer Refrigeration Units Please read this manual completely before attempting to install or operate this eq...

Страница 2: ......

Страница 3: ...NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPTING TO CLEAN OR SERVICE DO NOT USE EXTENSION CORDS WITH THIS EQUIPMENT DO NOT...

Страница 4: ...izing 5 Plumbing 5 Electrical Connection 5 OPERATION Refrigeration System 6 Temperature Monitoring 6 Control Panel 6 Defrost 6 Operating Controls 7 MAINTENANCE General Maintenance 7 8 Stainless Steel...

Страница 5: ...ly the necessary damage forms upon request 8 Retain all crating material until an inspection has been made or waived SPECIFICATIONS 115V 60Hz NOTE This manual covers standard units only If you have a...

Страница 6: ...5 80 0cm 34 86 4cm 4 230 240 50 7 2 2 1 3 BS1373 2 850 5g 327kg F2984VDR CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 230 240 50 3 6 1 3 BS1373 850 5g 236kg F2984VDL CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 23...

Страница 7: ...aning underneath The unit must be installed in a stable condition PLUMBING All models are standard with a condensate evaporator pan ELECTRICAL CONNECTION ELECTRICAL CONNECTIONS AND GROUNDING CONNECTIO...

Страница 8: ...le without tools REFRIGERATION SYSTEM In a 4 drawer system there are two compressors one operating drawers 1 and 2 and one operating drawers 3 and 4 In a 2 drawer system there is a single compressor T...

Страница 9: ...rate freeze chill or thaw untill desired mode is reached 3 Press the drawer display button again to lock the desired mode setting NOTE Text size will return to original size Activating Manual Defrost...

Страница 10: ...ere are also stainless steel cleaners available which can restore and preserve the finish of the steels protective layer Early signs of stainless steel breakdown can consist of small pits and cracks I...

Страница 11: ...ox When finished it should be wiped clean of all food and debris Tracks The drawer box assembly must be removed Pull the drawer tracks out until they hit a stop Locate blue safety clips towards the ba...

Страница 12: ...awer Refrigeration Units Delfield 980 S Isabella Road Mt Pleasant MI 48858 989 773 7981 or 800 733 8829 Fax 989 773 3210 2 Drawer Refrigeration Schematic The four drawer unit has two of these exact sy...

Страница 13: ...P2 COND 1 COND 2 J24 J25 COMP 1 1 J11 J26 COMP 2 1 J34 J35 J36 J9 J10 BOX BOX COIL COIL 1 J30 1 J29 12 VDC SWITCH EVAP FANS DRAWER LIMIT HEATER DRAWER FRAME BOX 1 12 VDC 7 2 1 MTR MTR EVAP FANS 8 SWIT...

Страница 14: ...1 1 J23 J19 J18 50 60 HZ 85 265 VAC CONTROL POWER BOARD CONNECTOR MAP 1 J28 D3 D4 VALVES J33 J32 COND FAN 2 1 SUCTION PRESSURE TRANSDUCER J24 AC HOT 1 J26 COMP 2 1 SP2 COIL J34 2 SIGNAL 3 COMMON J11 S...

Страница 15: ...BOX J5 J7 BOX J6 D3 COIL J8 D4 COIL J10 COND 1 J9 OUT J36 OUT IN COMP 1 J11 SP1 J35 IN J34 1 SP2 J26 COMP 2 1 J24 AC HOT 24 26 J33 J25 J32 1 2 COND FAN J28 D3 D4 VALVES 1 33 25 32 14 17 18 13 12 VDC M...

Страница 16: ...TO 1 3 TO 3 2 TO 2 3 SHIELD I O TO DISP BOX 13 17 COND 2 COIL COND 1 BOX COIL J9 COIL COIL D3 BOX J5 D1 J6 BOX 1 J1 J11 J2 BOX J10 D4 J36 COIL BOX J7 D2 J8 COIL J35 J3 J4 32 MTR BLACK COM 25 WHITE VO...

Страница 17: ...ture drops into range or probe is repaired Condenser temperature probe s out of range Temperature probe to condenser is damaged or temperature is out of range Press i button to suspend audio alarm for...

Страница 18: ...ant and leak check 55 00 USD maximum reimbursement for refrigerant recovery includes recovery machine pump torch oil flux minor fittings solder brazing rod nitrogen or similar fees A maximum travel di...

Страница 19: ...TOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition does this warranty give t...

Страница 20: ...mal control adjustments or maintenance food or business loss The one year Service Labor Contract shall cover those costs incurred by the Original Purchaser for a period of one 1 year from the date of...

Страница 21: ...he parts by the original part manufacturer This Service Labor Contract is offered on all Delfield units except remote refrigerators freezers and ventilation systems installed in the United States and...

Страница 22: ...its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was...

Страница 23: ......

Страница 24: ...__________________ Installation Date _____________ For a list of Delfield s authorized parts depots visit our website at www delfield com Mt Pleasant MI Covington TN 980 S Isabella Rd Mt Pleasant MI 4...

Отзывы: