In addition to the Standard One Year Warranty on the Motor-Compressor contained in the above listed Delfield prod

-

uct (the “Unit”), The Delfield Company (“Delfield”) also agrees to repair, or exchange with similar or interchangeable 

parts in design and capacity at Delfield’s option, the defective Motor-Compressor contained in the Unit (the “Motor-

Compressor”), or any part thereof, for the Original Purchaser only, at any time during the four (4) years following the 

initial one (1) year period commencing on the date of installation for the Original Purchaser. Failure of the Original 

Purchaser to register the registration card containing the Original Purchasers name, address, date of installation, 

model number and serial number of the Unit containing the Motor-Compressor within 30 days from the date of instal

-

lation shall void this warranty. This additional warranty is only available if the Motor-Compressor is inoperative due 

to defects in material or factory workmanship, as determined by Delfield in its sole judgement and discretion. The 

Original Purchaser shall be responsible for returning the defective Motor-Compressor to Delfield prepaid, F.O.B. at 

the address shown on the back cover of this manual.
The term “Original Purchaser” as used herein means that person, firm, association, or corporation for whom the 

Unit was originally installed.

The term “Motor-Compressor” as used herein does not include unit base, air or water cooled condenser, receiver, 

electrical accessories such as relay, capacitors, refrigerant controls, or condenser fan/motor assembly. This war

-

ranty does not cover labor charges incidental to the replacement of parts. This warranty further does not include 

any equipment to which said condensing unit is connected, such as cooling coils, temperature controls or refriger

-

ant metering devices. This warranty shall be void if the Motor-Compressor, in Delfield’s sole judgement, has been 

subjected to misuse, neglect, alteration or accident, operated contrary to the recommendations specified by the Unit 

manufacturer, repaired or altered by anyone other than Delfield in any way so as, in Delfield’s sole judgement, to 

affect its quality or efficiency or if the serial number has been altered, defaced or removed. This Warranty does not 

apply to a Motor-Compressor in any Unit that has been moved from the location where it was originally installed. 

The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty.

General Conditions

Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or result

-

ing from any contingency beyond Delfield’s control, including, but not limited to, war, governmental restrictions or 

restraints, strike, lockouts, injunctions, fire, flood, acts of nature, short or reduced supply of raw materials, or dis

-

continuance of any part or the Motor-Compressor by the unit manufacturer.
Replacement of a defective Motor-Compressor is limited to one (1) Motor-Compressor by us during the four (4) year 

period. Delfield shall replace the Motor-Compressor at no charge.
This  warranty  does  not  give  the  Original  Purchaser  of  the  Motor-Compressor  the  right  to  purchase  a  complete 

replacement Motor--Compressor of the same make or of another make. It further does not permit the replacement 

to be made with a Motor-Compressor of another kind unless authorized by Delfield. In the event Delfield authorizes 

the Original Purchaser to purchase a replacement Motor-Compressor locally, only the wholesale cost of the Motor-

-Compressor is refundable.
Expressly excluded from this warranty are damages resulting from spoilage of goods.
Except as provided in any applicable Standard One Year Limited Warranty or applicable Service Labor Contract, the 

foregoing is exclusive and in lieu of all other warranties, whether written or oral, express or implied. This Warranty 

supersedes and excludes any prior oral or written representations or warranties. Delfield expressly disclaims any 

implied  warranties  of  merchantability,  fitness  for  a  particular  purpose  or  compliance  with  any  law,  treaty,  rule  or 

regulation relating to the Motor--Compressor, and the full liability of Delfield for any breach of this warranty, will be 

as provided in this warranty.
Other than any applicable Delfield Standard One year Limited Warranty, this Delfield Additional Four Year Protection 

Plan and any applicable Delfield Service Labor Contract, the Original Purchaser agrees and acknowledges that no 

other warranties are offered or provided in connection with or for the Motor-Compressor or any part thereof.
In no event will Delfield be liable for special, incidental or consequential damages, or for damages in the nature of 

penalties.

Содержание Versa Drawer 18600VD

Страница 1: ...7981 or 800 733 8829 Fax 866 779 2040 www delfield com INSTALLATION OPERATION MANUAL Versa Drawer Refrigeration Units Please read this manual completely before attempting to install or operate this eq...

Страница 2: ......

Страница 3: ...NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPTING TO CLEAN OR SERVICE DO NOT USE EXTENSION CORDS WITH THIS EQUIPMENT DO NOT...

Страница 4: ...izing 5 Plumbing 5 Electrical Connection 5 OPERATION Refrigeration System 6 Temperature Monitoring 6 Control Panel 6 Defrost 6 Operating Controls 7 MAINTENANCE General Maintenance 7 8 Stainless Steel...

Страница 5: ...ly the necessary damage forms upon request 8 Retain all crating material until an inspection has been made or waived SPECIFICATIONS 115V 60Hz NOTE This manual covers standard units only If you have a...

Страница 6: ...5 80 0cm 34 86 4cm 4 230 240 50 7 2 2 1 3 BS1373 2 850 5g 327kg F2984VDR CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 230 240 50 3 6 1 3 BS1373 850 5g 236kg F2984VDL CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 23...

Страница 7: ...aning underneath The unit must be installed in a stable condition PLUMBING All models are standard with a condensate evaporator pan ELECTRICAL CONNECTION ELECTRICAL CONNECTIONS AND GROUNDING CONNECTIO...

Страница 8: ...le without tools REFRIGERATION SYSTEM In a 4 drawer system there are two compressors one operating drawers 1 and 2 and one operating drawers 3 and 4 In a 2 drawer system there is a single compressor T...

Страница 9: ...rate freeze chill or thaw untill desired mode is reached 3 Press the drawer display button again to lock the desired mode setting NOTE Text size will return to original size Activating Manual Defrost...

Страница 10: ...ere are also stainless steel cleaners available which can restore and preserve the finish of the steels protective layer Early signs of stainless steel breakdown can consist of small pits and cracks I...

Страница 11: ...ox When finished it should be wiped clean of all food and debris Tracks The drawer box assembly must be removed Pull the drawer tracks out until they hit a stop Locate blue safety clips towards the ba...

Страница 12: ...awer Refrigeration Units Delfield 980 S Isabella Road Mt Pleasant MI 48858 989 773 7981 or 800 733 8829 Fax 989 773 3210 2 Drawer Refrigeration Schematic The four drawer unit has two of these exact sy...

Страница 13: ...P2 COND 1 COND 2 J24 J25 COMP 1 1 J11 J26 COMP 2 1 J34 J35 J36 J9 J10 BOX BOX COIL COIL 1 J30 1 J29 12 VDC SWITCH EVAP FANS DRAWER LIMIT HEATER DRAWER FRAME BOX 1 12 VDC 7 2 1 MTR MTR EVAP FANS 8 SWIT...

Страница 14: ...1 1 J23 J19 J18 50 60 HZ 85 265 VAC CONTROL POWER BOARD CONNECTOR MAP 1 J28 D3 D4 VALVES J33 J32 COND FAN 2 1 SUCTION PRESSURE TRANSDUCER J24 AC HOT 1 J26 COMP 2 1 SP2 COIL J34 2 SIGNAL 3 COMMON J11 S...

Страница 15: ...BOX J5 J7 BOX J6 D3 COIL J8 D4 COIL J10 COND 1 J9 OUT J36 OUT IN COMP 1 J11 SP1 J35 IN J34 1 SP2 J26 COMP 2 1 J24 AC HOT 24 26 J33 J25 J32 1 2 COND FAN J28 D3 D4 VALVES 1 33 25 32 14 17 18 13 12 VDC M...

Страница 16: ...TO 1 3 TO 3 2 TO 2 3 SHIELD I O TO DISP BOX 13 17 COND 2 COIL COND 1 BOX COIL J9 COIL COIL D3 BOX J5 D1 J6 BOX 1 J1 J11 J2 BOX J10 D4 J36 COIL BOX J7 D2 J8 COIL J35 J3 J4 32 MTR BLACK COM 25 WHITE VO...

Страница 17: ...ture drops into range or probe is repaired Condenser temperature probe s out of range Temperature probe to condenser is damaged or temperature is out of range Press i button to suspend audio alarm for...

Страница 18: ...ant and leak check 55 00 USD maximum reimbursement for refrigerant recovery includes recovery machine pump torch oil flux minor fittings solder brazing rod nitrogen or similar fees A maximum travel di...

Страница 19: ...TOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition does this warranty give t...

Страница 20: ...mal control adjustments or maintenance food or business loss The one year Service Labor Contract shall cover those costs incurred by the Original Purchaser for a period of one 1 year from the date of...

Страница 21: ...he parts by the original part manufacturer This Service Labor Contract is offered on all Delfield units except remote refrigerators freezers and ventilation systems installed in the United States and...

Страница 22: ...its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was...

Страница 23: ......

Страница 24: ...__________________ Installation Date _____________ For a list of Delfield s authorized parts depots visit our website at www delfield com Mt Pleasant MI Covington TN 980 S Isabella Rd Mt Pleasant MI 4...