background image

8

Versa Drawer™ Refrigeration Units 

Delfield ·  980 S. Isabella Road, Mt. Pleasant, MI 48858 ·  (989) 773-7981 or (800) 733-8829 ·  Fax (989) 773-3210 

 

THE  UNIT  MUST  BE  DISCONNECTED  FROM  

THE POWER  SOURCE  WHENEVER  PERFORMING   

SERVICE,    MAINTENANCE    FUNCTIONS    OR  

CLEANING  THE  REFRIGERATED  AREA.

 

GENERAL MAINTENANCE

Stainless Steel Care and Cleaning

To prevent discoloration or rust on stainless steel 

several important steps need to be taken. First, the 

properties of stainless steel need to be understood. 

Stainless steel contains 70-80% iron that will rust. It 

also contains 12-30% chromium that forms an invisible 

passive film over the steel’s surface and acts as a 

shield against corrosion. As long as the protective 

layer is intact, the metal will not corrode, the metal is 

still stainless. If the film is broken or contaminated, 

outside elements can begin to break down the steel 

and begin to form rust or other discoloration.

Never use steel pads, wire brushes or scrapers!

Do not use an abrasive cleaner because it will scratch 

the stainless steel and plastic and can damage 

the breaker strips and gaskets. Proper cleaning of 

stainless steel requires soft cloths or plastic scouring 

pads.
Cleaning solutions need to be alkaline based or non-

chloride cleaners. Any cleaner containing chlorides 

will damage the protective film of the stainless steel. 

Chlorides are also commonly found in hard water, salts 

and household and industrial cleaners. If cleaners 

containing chlorides are used, be sure to rinse 

repeatedly and dry thoroughly upon completion.
Routine cleaning of the interior and exterior can be 

done with soap and warm water. Extreme stains or 

grease should be cleaned with a non-abrasive cleaner 

and plastic scrub pad. When cleaning the exterior, 

always rub with the grain of the stainless steel to 

avoid marring the finish. There are also stainless steel 

cleaners available which can restore and preserve the 

finish of the steels protective layer.
Early signs of stainless steel breakdown can consist 

of small pits and cracks. If this has begun, clean 

thoroughly and start to apply stainless steel cleaners in 
attempt to restore the passivity of the steel.

 

Never use an acid based cleaning solution! Many food 

products have an acidic content that can deteriorate 

the finish. Be sure to clean ALL food products from 

any stainless steel surface. Common items include, 

tomatoes, peppers and other vegetables.

Cleaning the Condenser Coil

The condenser coil requires regular cleaning, 

recommended is every 90 days. In some instances 

you may find that there is a large amount of debris and 

dust or grease accumulated prior to the 90-day time 

frame. In these cases the condenser coil should be 

cleaned as needed.
If the build up on the coil consists of only light dust and 

debris the condenser coil can be cleaned with a simple 

brush. Heavier dust build up may require a vacuum or 

compressed air to blow through the condenser coil.
If heavy grease is present there are de-greasing 

agents available for refrigeration use and specifically 

for the condenser coils. The condenser coil may 

require a spray with the de-greasing agent and then 

blown through with compressed air.
Failure to maintain a clean condenser coil can initially 

cause high temperatures and excessive run times. 

Continuous operation with dirty or clogged condenser 

coils can result in compressor failures. Neglecting 

condenser coil cleaning procedures will void any 

warranties associated with the compressor or cost to 

replace the compressor.

 

Never  use  a  high-pressure  water  wash  for  this 

cleaning  procedure  as  water  can  damage  the 

electrical  components  located  near  or  at  the 

condenser coil.

If your freezer seems to vibrate excessively when the 

compressor is running, loosen (but do not remove) the 

bolts on the compressor. Semi hermetic models should 

be loosened before operating.

Содержание Versa Drawer 18600VD

Страница 1: ...7981 or 800 733 8829 Fax 866 779 2040 www delfield com INSTALLATION OPERATION MANUAL Versa Drawer Refrigeration Units Please read this manual completely before attempting to install or operate this eq...

Страница 2: ......

Страница 3: ...NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPTING TO CLEAN OR SERVICE DO NOT USE EXTENSION CORDS WITH THIS EQUIPMENT DO NOT...

Страница 4: ...izing 5 Plumbing 5 Electrical Connection 5 OPERATION Refrigeration System 6 Temperature Monitoring 6 Control Panel 6 Defrost 6 Operating Controls 7 MAINTENANCE General Maintenance 7 8 Stainless Steel...

Страница 5: ...ly the necessary damage forms upon request 8 Retain all crating material until an inspection has been made or waived SPECIFICATIONS 115V 60Hz NOTE This manual covers standard units only If you have a...

Страница 6: ...5 80 0cm 34 86 4cm 4 230 240 50 7 2 2 1 3 BS1373 2 850 5g 327kg F2984VDR CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 230 240 50 3 6 1 3 BS1373 850 5g 236kg F2984VDL CE 84 213 4cm 31 5 80 0cm 26 66 0cm 2 23...

Страница 7: ...aning underneath The unit must be installed in a stable condition PLUMBING All models are standard with a condensate evaporator pan ELECTRICAL CONNECTION ELECTRICAL CONNECTIONS AND GROUNDING CONNECTIO...

Страница 8: ...le without tools REFRIGERATION SYSTEM In a 4 drawer system there are two compressors one operating drawers 1 and 2 and one operating drawers 3 and 4 In a 2 drawer system there is a single compressor T...

Страница 9: ...rate freeze chill or thaw untill desired mode is reached 3 Press the drawer display button again to lock the desired mode setting NOTE Text size will return to original size Activating Manual Defrost...

Страница 10: ...ere are also stainless steel cleaners available which can restore and preserve the finish of the steels protective layer Early signs of stainless steel breakdown can consist of small pits and cracks I...

Страница 11: ...ox When finished it should be wiped clean of all food and debris Tracks The drawer box assembly must be removed Pull the drawer tracks out until they hit a stop Locate blue safety clips towards the ba...

Страница 12: ...awer Refrigeration Units Delfield 980 S Isabella Road Mt Pleasant MI 48858 989 773 7981 or 800 733 8829 Fax 989 773 3210 2 Drawer Refrigeration Schematic The four drawer unit has two of these exact sy...

Страница 13: ...P2 COND 1 COND 2 J24 J25 COMP 1 1 J11 J26 COMP 2 1 J34 J35 J36 J9 J10 BOX BOX COIL COIL 1 J30 1 J29 12 VDC SWITCH EVAP FANS DRAWER LIMIT HEATER DRAWER FRAME BOX 1 12 VDC 7 2 1 MTR MTR EVAP FANS 8 SWIT...

Страница 14: ...1 1 J23 J19 J18 50 60 HZ 85 265 VAC CONTROL POWER BOARD CONNECTOR MAP 1 J28 D3 D4 VALVES J33 J32 COND FAN 2 1 SUCTION PRESSURE TRANSDUCER J24 AC HOT 1 J26 COMP 2 1 SP2 COIL J34 2 SIGNAL 3 COMMON J11 S...

Страница 15: ...BOX J5 J7 BOX J6 D3 COIL J8 D4 COIL J10 COND 1 J9 OUT J36 OUT IN COMP 1 J11 SP1 J35 IN J34 1 SP2 J26 COMP 2 1 J24 AC HOT 24 26 J33 J25 J32 1 2 COND FAN J28 D3 D4 VALVES 1 33 25 32 14 17 18 13 12 VDC M...

Страница 16: ...TO 1 3 TO 3 2 TO 2 3 SHIELD I O TO DISP BOX 13 17 COND 2 COIL COND 1 BOX COIL J9 COIL COIL D3 BOX J5 D1 J6 BOX 1 J1 J11 J2 BOX J10 D4 J36 COIL BOX J7 D2 J8 COIL J35 J3 J4 32 MTR BLACK COM 25 WHITE VO...

Страница 17: ...ture drops into range or probe is repaired Condenser temperature probe s out of range Temperature probe to condenser is damaged or temperature is out of range Press i button to suspend audio alarm for...

Страница 18: ...ant and leak check 55 00 USD maximum reimbursement for refrigerant recovery includes recovery machine pump torch oil flux minor fittings solder brazing rod nitrogen or similar fees A maximum travel di...

Страница 19: ...TOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition does this warranty give t...

Страница 20: ...mal control adjustments or maintenance food or business loss The one year Service Labor Contract shall cover those costs incurred by the Original Purchaser for a period of one 1 year from the date of...

Страница 21: ...he parts by the original part manufacturer This Service Labor Contract is offered on all Delfield units except remote refrigerators freezers and ventilation systems installed in the United States and...

Страница 22: ...its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was...

Страница 23: ......

Страница 24: ...__________________ Installation Date _____________ For a list of Delfield s authorized parts depots visit our website at www delfield com Mt Pleasant MI Covington TN 980 S Isabella Rd Mt Pleasant MI 4...