Part Number GA_SM 08/18
53
Section 7
Component Check Procedures
6. Rotate the door hinge 160°-180°.
7. Hold the hinge, twist the door and slide the top pin into
the top hinge.
8. Screw the bottom hinge to the unit.
9. Check the door alignment. Check that it shuts and
seals. Adjust the bottom hinge if necessary.
Temperature Probe Resistance
Part 2195702
5KΩ NTC Temperature Probe
Temperature
in °C
Temperature
in °F
Resistance (Ω)
Nominal
-20
-4
48,560
-19
-2.2
45,835
-18
-0.4
43,275
-17
1.4
40,870
-16
3.2
38,610
-15
5
36,490
-2
28.4
18,100
-1
30.2
17,190
**0
32
16,330
1
33.8
15,520
2
35.6
14,755
3
37.4
14,030
4
39.2
13,345
5
41
12,700
20
68
6,245
21
69.8
5,970
22
71.6
5,710
23
73.4
5,460
24
75.2
5,225
25
77
5,000
** Resistance if probe is placed in an ice bath.
Содержание Specification Line GA Series
Страница 6: ...6 Part Number GA_SM 08 18 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 20: ...20 Part Number GA_SM 08 18 Installation Section 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 36: ...36 Part Number GA_SM 08 18 Troubleshooting Section 5 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 48: ...48 Part Number GA_SM 08 18 Control Section 6 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 56: ...56 Part Number GA_SM 08 18 Component Check Procedures Section 7 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 94: ...94 Part Number GA_SM 08 18 Refrigeration Section 8 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 102: ...102 Part Number GA_SM 08 18 Diagrams Section 9 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 103: ......