22
Part Number GA_SM 08/18
Operation
Section 3
!
!
5. The unit will continue though the Defrost mode. The
compressor and condenser fan as well as the evaporator
fan will remain off until this initial defrost is complete.
This initial defrost cycle may take up to 35 minutes to
complete.
6. The defrost icon will continue on the display for an
additional 30 minutes while the cooling cycle cools the
box to the set temperature. Then the box temperature
will be displayed.
!
°
F
32
!
7. The temperature control will cycle the compressor,
evaporator fan motor and condenser fan motor to
maintain box temperature at the control setting.
EVAPORATOR FAN OPERATION
During normal operation the evaporator fan may cycle and/
or pulse independently of the compressor. Consult Technical
Support at 1-844-724-CARE if you are unsure of the proper
function.
Cooling Cycle
Defrost Cycle
Compressor
On
Compressor Off
Compressor
Off
Refrigerator
Evap Fan On
Cycles On 2-Min,
Off 2-Min
Evap Fan On
Freezer
Evap Fan On
Evap Fan Off
Evap Fan Off
Heated Cabinet Operation
DANGER
The unit surface is very hot! Avoid direct contact with
skin; use appropriate protective apparel, such as gloves.
Delfield heated cabinets are designed to maintain an
operational temperature of 165°F (73°C).
Heated Cabinet Start Up
This also covers anytime power is disconnected then
reconnected.
1. Plug the unit in.
2. The screen will appear after a 30 second delay.
3. Select the power icon, located on the right of the screen.
!
!
4. The home screen will display. Allow unit to warm-up
before use. It may take up to two hours to reach the
desired temperature.
!
°
F
32
!
64
FAN OPERATION
When heating elements are ON, fan is ON.
When heating elements are OFF, fan cycles OFF for 2
minutes, then ON for 1 minute and repeating this cycle until
control turns heating elements back ON.
Содержание Specification Line GA Series
Страница 6: ...6 Part Number GA_SM 08 18 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 20: ...20 Part Number GA_SM 08 18 Installation Section 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 36: ...36 Part Number GA_SM 08 18 Troubleshooting Section 5 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 48: ...48 Part Number GA_SM 08 18 Control Section 6 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 56: ...56 Part Number GA_SM 08 18 Component Check Procedures Section 7 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 94: ...94 Part Number GA_SM 08 18 Refrigeration Section 8 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 102: ...102 Part Number GA_SM 08 18 Diagrams Section 9 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 103: ......