Note!
Note!
Note!
Note! The MM27BC is sensitive when it
comes to vacuum leaks, restrictions and blocks
so it is of great importance that the installation
is according to guidelines.
When the installation is checked and approved
proceed with the actual calibration process:
Verify that it is clean, without cracks. Liners
and stubs should also be in a good condition
without cracks. Check also the air bleed on
the claw so that it is not blocked.
4.
4.
4.
4. Check and verify that there are no error
messages on the MM27BC display when it
is connected to the power.
1.
1.
1.
1. Connect the IR reader to the VPR100
20
38
35
2.
2.
2.
2. In the VPR100 go to menu for MM25W/
MM27BC. Choose ALCOM. Use the
VPR100 to read all Alcom node number in
the parlour. Mark node number on a piece
of Tape on each milkmeter. Make sure no
milkmeter has the same number. If there are
units with the same number reset them to
another nr by punching in new number on
the VPR100 and sending it to the milkmeter.
3.
3.
3.
3. Setup Buckets at milking point. Mark each
bucket with node number so that it belongs
to that specific milking point.
4.
4.
4.
4. When the milking is done push calibration
on the VPR100 and read the milking points
with buckets by pointing reader to the milk-
meter. The VPR100 will automatically
DeLaval milk meter MM27BC
DeLaval milk meter MM27BC
DeLaval milk meter MM27BC
DeLaval milk meter MM27BC
161 Preventive maintenance