Preparing for installation.

 

The extractor hood has the ability to ei-
ther recirculate the filtered air back into 
the kitchen, or to vent the filtered air 
through an outside wall.   
Decide on which option best suits you be-
fore commencing with the installation. 

• 

The extractor hood is intended to be 
mounted onto a flat perpendicular kitchen 
wall capable of supporting the weight of 
the hood. (approximately 16 to 26 kg de-
pending on the model). 

Tools required for installation: 

• 

An electric drill. 

• 

 A  3.5 mm diam. steel drill bit. 

• 

8mm and 5mm diam. masonry drill bits 

• 

A star screw driver (Posi 2). 

• 

A ratchet with a 10mm socket and a 
100mm extension. 

• 

A tape measure, masking tape and a pen-
cil. 

  

Venting air to the outside.

 

When discharging the air into a ventila-
tion shaft or directly through the wall 
into the open , please take note of the fol-
lowing: 

• 

Exhaust air from the extractor hood 
must not be directed into a flue or 
chimney which is used for exhausting 
the fumes or smoke from other appli-
ances burning gas or fuels. 

• 

Please ensure that regulations concern-
ing the discharge of exhaust air have 
been fulfilled. (SABS IEC 60335-2-31). 

 
For optimum extractor hood efficiency use 
a short, smooth, round air exhaust pipe with 
as few bends as possible A 150mm diameter 
exhaust pipe is recommended. Long box 
section, narrowed or bent pipes will hinder 
performance and increase noise levels. 

• 

Connecting a 150 mm diameter pipe: 

Mount the pipe directly onto the air outlet 
on the extractor hood. 

• 

Connecting a 125 mm or 100mm di-
ameter pipe: 

Attach a reducing connec-

tor (available from a  specialist retailer) 
to the air pipe and then attach to the ex-
haust-air duct.  

DESCRIPTION

ITEM

QUANTITY

8mm wall plug
6mm screw
5mm wall plug
5mm screw

Self tapping screw

Slotted washer

  4

  6

10

  4

Care must be taken during installation not 
to obstruct these vents. 
No ducting is required for this type of in-
stallation.

 

 

The extractor hood filters out solid particles 
before the air is recirculated, via the vents 
on the side of the upper chimney, into the 
kitchen.

 

  Recirculating filtered air. 

Recirculate

filtered air

 

Exhaust air through a dedicted pipe 

not shared with another fuel burning appliance.

ceiling

 

 

ceiling

ceiling

Содержание DCH260

Страница 1: ... improvements For this reason the text and illustrations in this book are subject to change without notice Part Number 066044 INDEX 2 Description 2 Before use 2 Safety advice 2 Electrical connection 3 Preparing for installation 3 Recirculating filtered air 3 Venting air to the outside 4 Installation 6 Grease filters 6 Optional carbon pad filters 7 Operation 7 Replacing the light bulbs 8 Maintenanc...

Страница 2: ...nd the chimney area A qualified electrician should provide this facility The extractor hood must be earthed The manufacturer and the seller do not accept responsibility for any dam age due to incorrect electrical connec tion This extractor hood may not be used with a battery inverter power supply Before use This extractor hood complies with all relevant safety regulations The extractor hood is not...

Страница 3: ... burning gas or fuels Please ensure that regulations concern ing the discharge of exhaust air have been fulfilled SABS IEC 60335 2 31 For optimum extractor hood efficiency use a short smooth round air exhaust pipe with as few bends as possible A 150mm diameter exhaust pipe is recommended Long box section narrowed or bent pipes will hinder performance and increase noise levels Connecting a 150 mm d...

Страница 4: ...iangular 900 are marked with a 2 Holes not marked are common to all models For mounting the chimney brackets drill 6 holes 5mm in diameter and 45mm deep into the wall as indicated on the mounting template For mounting the extractor hood drill 4 holes 8mm in diameter and 60mm deep as indicated on the mounting template Once all the holes have been drilled the templates must be removed Push the 5mm D...

Страница 5: ...ve film from the chimney ducting taking care not to dam age the polished stainless steel surface Fit the upper chimney duct section the one with louvre outlets to the ceiling mounting bracket using the screws sup plied INSERT 6 SELF TAPPING SCREWS Fit the lower chimney duct to the lower wall mounting bracketand tighten the six screws on the inside of the extractor hood Drill 3 5mm Dia holes throug...

Страница 6: ...and release the catch To remove the filter for cleaning pur poses reverse the procedure described above Grease filters Carbon pad filters assist in removing any unwanted cooking odours from the at mosphere If your installation ducts filtered air to the outside the carbon pad filters are not re quired Should you require them factory ap proved carbon pad filters and installation kits may be purchase...

Страница 7: ... equivalent bulb Fit the glass cover and replace the re taining ring Switch on the electricity supply Select the fan speed you require Push button 3 for high extraction level Push button 2 for medium Push button 1 for low The fan indicator light will glow when the fan is operating To switch the fan off push the motor speed OFF button 0 If required you may illuminate the cooking area by switching t...

Страница 8: ...ree soft cloth or synthetic sponge Soap or mild liquid detergent A mild window cleaner Diluted ammonia in warm water A nylon bristle brush Cleaners labelled Suitable for stainless steel Do not use A steam cleaner Acid alcohol soda chloride or spirit based cleaners Coarse abrasive cleaning powders Metallic scourers steel wool metal scrapers or plastic scouring pads Wire brushes or emery paper So ca...

Страница 9: ...e agents Consult the nearest regional service centre for details BLOEMFONTEIN 160 Long Street Hilton Bloemfontein 9301 Tel 051 400 3900 Bloemfontein Service defy co za CAPE TOWN 5A Marconi Rd Montague Gardens 7441 Tel 021 551 8314 CapeTown Service defy co za DURBAN 35 Intersite Avenue Umgeni Business Park Durban 4051 Tel 031 268 3300 Durban Service defy co za EAST LONDON 16 Bowls Rd Arcadia East L...

Страница 10: ...ition of these warranties that the purchaser takes due care and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating in structions connection to incorrect voltages and subjection to commercial use shall release the Company from its obligations 3 This warranty shall become void and cease to operate if the appliance is dismantled by or any re pairs to the app...

Отзывы: