Replacing the light bulbs. 

Glass cover

Retaining ring

Housing

Light bulb

• 

Switch off the electricity supply. 

• 

If the bulb has recently failed, it 
might still be very hot. Allow the glass 
cover to cool before attempting to re-
place the bulb. 

• 

Hold the glass cover and unclip the re-
taining ring. Be careful not to let the 
glass cover fall. 

• 

Replace the light bulb with a commer-
cially available OSRAM 12V 20W 
(64425) or equivalent bulb. 

• 

Fit the glass cover and  replace the re-
taining ring. 

• 

Switch on the electricity supply. 

• 

Select the fan speed you require.  

• 

Push button ‘3’ for high extraction level. 

• 

Push button ‘2’ for medium. 

• 

Push button ‘1’ for low. 

• 

The fan indicator light will glow when 
the fan is operating. 

• 

To switch the fan off, push the motor 
speed OFF button ‘0’. 

• 

If required, you may illuminate the 
cooking area by switching the hood 
lights on. 

• 

Leave the hood running for a short pe-
riod after the cooking has been com-
pleted to clear any smoke and odours. 

  Operation. 

Lights
on/ off

Fan speed

Fan

indicator

light

0

1

2

3

Motor speed 

Off button 

Содержание DCH260

Страница 1: ... improvements For this reason the text and illustrations in this book are subject to change without notice Part Number 066044 INDEX 2 Description 2 Before use 2 Safety advice 2 Electrical connection 3 Preparing for installation 3 Recirculating filtered air 3 Venting air to the outside 4 Installation 6 Grease filters 6 Optional carbon pad filters 7 Operation 7 Replacing the light bulbs 8 Maintenanc...

Страница 2: ...nd the chimney area A qualified electrician should provide this facility The extractor hood must be earthed The manufacturer and the seller do not accept responsibility for any dam age due to incorrect electrical connec tion This extractor hood may not be used with a battery inverter power supply Before use This extractor hood complies with all relevant safety regulations The extractor hood is not...

Страница 3: ... burning gas or fuels Please ensure that regulations concern ing the discharge of exhaust air have been fulfilled SABS IEC 60335 2 31 For optimum extractor hood efficiency use a short smooth round air exhaust pipe with as few bends as possible A 150mm diameter exhaust pipe is recommended Long box section narrowed or bent pipes will hinder performance and increase noise levels Connecting a 150 mm d...

Страница 4: ...iangular 900 are marked with a 2 Holes not marked are common to all models For mounting the chimney brackets drill 6 holes 5mm in diameter and 45mm deep into the wall as indicated on the mounting template For mounting the extractor hood drill 4 holes 8mm in diameter and 60mm deep as indicated on the mounting template Once all the holes have been drilled the templates must be removed Push the 5mm D...

Страница 5: ...ve film from the chimney ducting taking care not to dam age the polished stainless steel surface Fit the upper chimney duct section the one with louvre outlets to the ceiling mounting bracket using the screws sup plied INSERT 6 SELF TAPPING SCREWS Fit the lower chimney duct to the lower wall mounting bracketand tighten the six screws on the inside of the extractor hood Drill 3 5mm Dia holes throug...

Страница 6: ...and release the catch To remove the filter for cleaning pur poses reverse the procedure described above Grease filters Carbon pad filters assist in removing any unwanted cooking odours from the at mosphere If your installation ducts filtered air to the outside the carbon pad filters are not re quired Should you require them factory ap proved carbon pad filters and installation kits may be purchase...

Страница 7: ... equivalent bulb Fit the glass cover and replace the re taining ring Switch on the electricity supply Select the fan speed you require Push button 3 for high extraction level Push button 2 for medium Push button 1 for low The fan indicator light will glow when the fan is operating To switch the fan off push the motor speed OFF button 0 If required you may illuminate the cooking area by switching t...

Страница 8: ...ree soft cloth or synthetic sponge Soap or mild liquid detergent A mild window cleaner Diluted ammonia in warm water A nylon bristle brush Cleaners labelled Suitable for stainless steel Do not use A steam cleaner Acid alcohol soda chloride or spirit based cleaners Coarse abrasive cleaning powders Metallic scourers steel wool metal scrapers or plastic scouring pads Wire brushes or emery paper So ca...

Страница 9: ...e agents Consult the nearest regional service centre for details BLOEMFONTEIN 160 Long Street Hilton Bloemfontein 9301 Tel 051 400 3900 Bloemfontein Service defy co za CAPE TOWN 5A Marconi Rd Montague Gardens 7441 Tel 021 551 8314 CapeTown Service defy co za DURBAN 35 Intersite Avenue Umgeni Business Park Durban 4051 Tel 031 268 3300 Durban Service defy co za EAST LONDON 16 Bowls Rd Arcadia East L...

Страница 10: ...ition of these warranties that the purchaser takes due care and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating in structions connection to incorrect voltages and subjection to commercial use shall release the Company from its obligations 3 This warranty shall become void and cease to operate if the appliance is dismantled by or any re pairs to the app...

Отзывы: