4
3
2
1
A
L
A
R
M
Junc�on
Box Cover
Not Used
Power
Cable
Power Spli�er
Exit
Fi�ng
Alarm Cable
Ethernet
Cable
Alarm
Cable
To Camera →
Junc�on
Box
Access
Hole
The connections shown below will be made inside of the Junction Box.
Refer to the diagram and the following sections in this manual:
Connec�ons inside of the Junc�on Box
After drilling the access hole, remove the Junction Box cover and rear
knockout. Center the box over the hole to test fit. Position the exit fitting
(used for Alarm Module wiring) where desired. When satisfied, spread
caulk around the outside back of the Junction Box, leaving a small space at
the bottom for water to run out. Fasten the Junction Box using the
included hardware. If the hardware is not suitable for the mounting
surface, use appropriate hardware purchased separately.
With the cover off, test fit the Power Splitter cable inside of the Junction
Box and run the 4 conductor end of the Alarm Cable out of the Junction
Box exit fitting. This should give you an estimate of where the Alarm
Module can be mounted (within approximately 3 feet of the camera).
8
Junc�on Box
Installa�on