With the Alarm Cable connected, you can now mount the Alarm Module.
Mount the alarm in the desired location. If the included hardware is not
suitable for the mounting surface, use appropriate hardware purchased
separately. Route the Alarm Cable in manner where it will not get pinched
when the Alarm Module is fastened.
Alarm
Cable
A
LA
R
M
3
2
1
4
1 White
2 Yellow
3
Not used
4
Not used
1 2 3 4
1 Yellow & Red
2 Black
3
Not used
4 White
ALARM
Power
Spli�er
Alarm
Connector
As shown below, the one side of the Power Splitter will plug into the
PoolScout Alarm Cable. The Alarm Cable power connector will come
prewired to the RED and BLK conductors. In addition to the power
connector, there are two additional conductors (WHT and YEL) that must
be wired to the
camera’s alarm connector. With the cover removed, connect the 4
conductors of the Alarm Cable to the screw terminal block inside of the
Alarm Module as shown below. Route the Alarm Cable from the back of
the Alarm Module according to the diagram.
Carefully coil excess wire into the Junction Box and fasten the cover using
the original hardware. The camera can now be mounted onto the Junction
Box cover.
11
Wired Alarm
Installa�on