8. Fix the remaining flat roof profiles to the mounting
rails as described in steps 2-4 and fasten the legs
with the M8x18mm cheese-head bolts.
See chapter 5.1 Dimensions of and spacings be-
tween flat-roof iron corners, page 19 for the distanc-
es between the profiles.
9. Turn the solar-panel supporting frame over so that
the T-section braces are at the bottom and position
it according to the plans.
10.Make the solar-panel supporting frame stable and
secure (by fixings or weights).
If the solar-panel supporting frame is not screwed to
the structure of the roof, it must be weighted down
as appropriate for the site and conditions. Slabs
such as lawn edging stones (60) (1000x250x80) are
suitable as stabilising weights. Slabs with the above
dimensions will fit exactly between the aluminium T-
section braces.
Flat roof installation
up to 8 m.
3 panels
336 kg
5 panels
672 kg
8 panels
1008 kg
The permissible roof load must not under
any circumstances be exceeded. Consult a
structural engineer beforehand if neces-
sary. If it is necessary to penetrate the roof
surface, care must be taken to ensure that it is made
properly waterproof again.