Maximum domestic hot water temperature without electrical back-up
°C
65
Maximum domestic hot water temperature with electrical back-up
°C
75
Vmax (Maximum usable volume of hot water)
(1)
l
303.1
Modulating air flow rate (Maximum)
m
3
/h
265
Modulating air flow rate (Minimum)
m
3
/h
35
Available air pressure
(3)
Pa
100 or 125
Sound output
dB(A)
54
R–134a refrigerant
kg
0.85
R-134a refrigerant
(4)
tCO
2
e
1.22
Tilting dimension
mm
1755
Weight (empty)
kg
92
(1) Value obtained with an air temperature of 20°C and a wet temperature of 16.5°C. Water inlet temperature of 10°C. Cycle L
(2) Value obtained with an air temperature of 20°C and a wet temperature of 16.5°C. Water inlet temperature of 10°C. Cycle L
(3) According to the configuration, see the Operating principle section
(4) Quantity of refrigerant calculated in tonnes of CO
2
equivalent.
Important
The R-134a refrigerant is contained in equipment that has been
hermetically sealed.
For more information, see
Operating principle, page 16
3 Technical specifications
14
TWH 200 EV
EN-7602142 - v11 - 24042019