4 Installation

4.1

Package list

4.1.1.

Standard delivery

The delivery includes:

4

The control panel with the IniControl module

4

Installation, use and maintenance manual for the control panel

4.1.2.

Accessories

Various options are available depending on the configuration of the

installation:

Control system options
Description

package

BUS connection cable (length 12 m)

AD134

voice remote monitoring module

AD152

OpenTherm interface

AD287

Outside sensor

FM46

RX11 cable

AD124

Modulating room thermostat

AD265

Radio-controlled modulating room thermostat AD266
Digital room thermostat

AD137

Wireless settable ambient thermostat

AD200

SCU-S05 PCB
SCU-S03 PCB

4.2

Installing the outside sensor

4.2.1.

Choice of the location

It is important to select a place that allows the sensor to measure the

outside conditions correctly and effectively.

Advised positions:

4

on one face of the area to be heated, on the north if possible

4

half way up the wall in the room to be heated

4

under the influence of meteorological variations

4. Installation

IniControl For C 330 / C 630 ECO

9

260216 - 7600717-001-06

Содержание IniControl

Страница 1: ...Ireland EN Regulation IniControl For C 330 C 630 ECO C003108 A Installation User and Service Manual 7600717 001 06...

Страница 2: ...nsor 9 4 2 1 Choice of the location 9 4 2 2 Connecting the outside sensor 10 4 3 Fitting and connecting the control panel 10 4 4 Electrical connections 11 4 4 1 Connecting a direct heating circuit 11...

Страница 3: ...5 4 5 Setting the maximum heat input for central heating operation 25 5 4 6 Return to the factory settings Reset Param 26 5 4 7 Carrying out an auto detect 26 5 4 8 Setting the manual mode 27 6 Troubl...

Страница 4: ...3 260216 7600717 001 06...

Страница 5: ...cal injury WARNING Risk of a dangerous situation causing slight physical injury CAUTION Risk of material damage Signals important information Signals a referral to other instructions or other pages in...

Страница 6: ...compliance with the prevailing legislation and standards 4 Perform the initial start up and carry out any checks necessary 4 Explain the installation to the user 4 If a maintenance is necessary warn t...

Страница 7: ...re that children do not play with the appliance If the mains power lead is damaged it must be replaced by the original manufacturer the manufacturer s dealer or another competent person to prevent haz...

Страница 8: ...and heating equipment must be carried out by a qualified engineer For a proper operating of the boiler follow carefully the instructions Keep this document close to the place where the boiler is inst...

Страница 9: ...1342 1149 984 842 720 616 528 454 Specifications of the flow sensor circuit B C Specifications of the DHW sensor Specifications of the system sensor Temperature in C 0 10 20 25 30 40 50 60 70 80 90 Re...

Страница 10: ...sensor FM46 RX11 cable AD124 Modulating room thermostat AD265 Radio controlled modulating room thermostat AD266 Digital room thermostat AD137 Wireless settable ambient thermostat AD200 SCU S05 PCB SC...

Страница 11: ...uptive heat source sun chimney ventilation grid etc 4 2 2 Connecting the outside sensor Mount the sensor using the screws and dowels provided A Inserts Z 4 wood screw For the connection of the outside...

Страница 12: ...afety thermostat to the connector 4 4 2 Connection in cascade with OpenTherm AD287 option A Master boiler DIEMATIC iSystem Z Secondary boiler DIEMATIC iSystem or IniControl E Secondary boiler DIEMATIC...

Страница 13: ...he Opentherm from the PCU to the Opentherm on the interface P OpenTherm AD287 interface board to be fitted in the boiler control panel a Encoding wheel used to set the addresses of the slave boilers S...

Страница 14: ...or Manual reset t B Heating temperature button d or C DHW temperature button r or D S Enter Key E Chimney sweeping keys Press keys A and B simultaneously F f Menu keys Press keys C and D simultaneousl...

Страница 15: ...tivated r State DHW pump S DHW off m Manual mode m The DHW function is in economic mode deactivated g Boiler protection is active n Flame output level e Low output level 0 25 r Average output level 25...

Страница 16: ...and switched on again before resetting I Outside temperature sensor present M The symbol is displayed when the boiler pump is operating a Defect Boiler indicates a fault This is indicated by an E code...

Страница 17: ...lay Check the mains supply voltage Check the main fuses Check the fuses on the control panel F1 2 AT F2 8 AT Check the connection of the mains lead to the connector in the instrument box 4 A fault is...

Страница 18: ...from the hour counter and percentage of successful starts 1 Press the two keys f simultaneously and then key until the symbol flashes on the menu bar 2 Press the S key hr and the number of hours of bo...

Страница 19: ...nal set point 32 Output control 33 Temperature protection gradient level 1 Modulate down 34 Temperature protection gradient level 2 Part load 35 Temperature protection gradient level 3 Blockage 36 Mod...

Страница 20: ...tinuous 5 5 5 5 5 5 p3 Boiler regulation 0 Heating deactivated 1 Heating activated 1 1 1 1 1 1 p4 Display screen 0 Simple 1 Comprehensive 2 Automatic switching to simple after 3 minutes 3 Automatic sw...

Страница 21: ...HdV If connected 0 to 255 seconds 0 0 0 0 0 0 p31 Flue gas damper running time FgV If connected 0 to 255 seconds 0 0 0 0 0 0 p32 Release waiting time 0 to 255 seconds 0 0 0 0 0 0 p33 Gas valve leak p...

Страница 22: ...Adjustment range Factory setting C 630 ECO 560 700 860 1000 1140 1300 p1 Flow temperature TSET 20 to 90 C 80 80 80 80 80 80 p2 Post circulation of the pump 1 to 98 minutes 99 minutes continuous 5 5 5...

Страница 23: ...cted 0 0 0 0 0 0 p30 Hydraulic valve running time HdV If connected 0 to 255 seconds 0 0 0 0 0 0 p31 Flue gas damper running time FgV If connected 0 to 255 seconds 0 0 0 0 0 0 p32 Release waiting time...

Страница 24: ...0 10 10 10 10 10 p45 TModulate down 10 to 30 C 25 25 25 25 25 25 Zd Detection of connected SCUs 0 No detection 1 Detection 0 0 0 0 0 0 df and dV Factory setting To restore the factory settings or when...

Страница 25: ...es to return to the current operating mode The parameters p002 to p007 are changed in the same way as p001 After step 2 use the key to move to the required parameter 5 4 4 Modification of the installe...

Страница 26: ...operating status if no keys are pressed for 3 minutes 5 4 5 Setting the maximum heat input for central heating operation The speed can be changed using parameter p17 To do this proceed as follows 1 P...

Страница 27: ...for CN2 Check this against the value of Y on the type plate 9 Enter the value of Y shown on the type plate using the or key 10 Confirm the value with the j key The factory settings are reset 11 The di...

Страница 28: ...the menu bar 2 Press the S key or The text Zv with the current water pressure only if an outside sensor is connected The flow temperature is determined by the internal heating curve or The value of th...

Страница 29: ...rs with Recom 5v 1 Maximum flow temperature exceeded The water flow in the installation is insufficient 4 Check the circulation direction pump valves 5v 2 Maximum increase of the flow temperature has...

Страница 30: ...error 4 Reset df and dV 4 Restore parameters with Recom Bad connection 4 Check the wiring 5v 9 Phase and neutral of mains supply mixed up 4 Mains supply incorrectly wired 4 Floating or 2 phase network...

Страница 31: ...tting of the gas valve unit 4 Check that the air inlet and flue gas discharge flues are not blocked 4 Check that there is no recirculation of flue gases 5v 25 Internal error on the SU PCB 4 Replace th...

Страница 32: ...pump valves 4 Check the water pressure 4 Check the cleanliness of the heat exchanger e 05 Exchanger temperature too high Bad connection 4 Check the wiring between the PCU PCB and the sensor 4 Check t...

Страница 33: ...he heating system 4 Check the circulation direction pump valves 4 Check the water pressure 4 Check the cleanliness of the heat exchanger e 10 Difference insufficient between the exchanger temperature...

Страница 34: ...he ignition transformer 4 Check that the SU PCB is correctly in place 4 Check the ionization ignition electrode 4 Check the earthing 4 SU PCB faulty Change the PCB Ignition arc but no flame formation...

Страница 35: ...turn reversed Bad connection 4 Check that the sensor has been correctly fitted Sensor fault 4 Check the Ohmic value of the sensors 4 Replace the sensor if necessary Water circulation direction reverse...

Страница 36: ...lers menu using the key S c0de appears on the display 3 Use keys or to input the installer code 0012 4 Press the S key er xx appears on the display 5 The fault list or shutdown list can be displayed b...

Страница 37: ...The fault list or shutdown list can be displayed by pressing the or key 6 Confirm using key S er xx is displayed with xx flashing 7 Press the key several times until er cl is displayed on the screen 8...

Страница 38: ......

Страница 39: ......

Страница 40: ...0 271 001 627 dedietrich bdrthermea cz IT DE DIETRICH THERMIQUE Iberia S L U www dedietrich calefaccion es C Salvador Espriu 11 08908 L HOSPITALET de LLOBREGAT 34 935 475 850 info dedietrich calefacci...

Отзывы: