Code
Message
Description
H.02.23
SYSTEM FLOW ERROR
Insufficient flow rate
Open a radiator valve
The circuit is clogged
Check that the filters are not obstructed
Clean and flush the installation
H.02.36
FUNCTIONAL DEVICE
DISCONNECTED
No communication with the PCB SCB-04
H.02.37
UNCRITICAL DEVICE
DISCONNECTED
No communication with the PCB SCB-04
H.06.01
HP UNIT FAILURE
Heat pump outdoor unit defective.
H.00.00
SENS T FLOW OPEN
Hybrid heat pump flow sensor defective
H.00.01
SENS T FLOW CLOSED
Hybrid heat pump flow sensor defective
H.00.16
SENS DHW OPEN
Bottom domestic hot water temperature sensor defective
H.00.17
SENS DHW CLOSED
Bottom domestic hot water temperature sensor defective
H.00.32
SENS T OUTSIDE OPEN
Outside temperature sensor defective
H.00.33
SENS T OUTSIDE CLOSED
Outside temperature sensor defective
H.00.40
SENS WATPRESSURE OPENS
Error on the water pressure sensor
H.00.41
SENS WATPRESSURE
CLOSEDS
Error on the water pressure sensor
H.00.47
SENS HP FLOW OPEN
Heat pump flow temperature sensor defective
H.00.48
SENS HP FLOW CLOSED
Heat pump flow temperature sensor defective
H.00.51
SENS HP RETURN OPEN
Heat pump return temperature sensor defective
H.00.52
SENS HP RETURN CLOSED
Heat pump return temperature sensor defective
H.00.57
SENS DHW TOP OPEN
Top domestic hot water temperature sensor defective
H.00.58
SENS DHW TOP CLOSED
Top domestic hot water temperature sensor defective
H.02.00
RESET IN PROGRESS
Reset under way
H.02.02
WAITING FOR CONFIGURATION
NUMBER
The heat pump is not configured
H.02.03
CONFIGURATION ERROR
The heat pump is not configured
H.02.04
PARAMETER ERROR
Incorrect parameter configuration
H.02.05
PSU
Internal error
H.02.07
WATPRESSURE ERROR
Insufficient water pressure
H.02.09
PARTIAL BLOCK
The BL input on the terminal block in the EHC-02 PCB is open
H.02.10
FULL BLOCK
The BL input on the terminal block in the EHC-02 PCB is open
H.02.23
SYSTEM FLOW ERROR
Insufficient flow rate
H.02.36
FUNCTIONAL DEVICE
DISCONNECTED
No communication with the PCB SCB-04
H.02.37
UNCRITICAL DEVICE
DISCONNECTED
No communication with the PCB SCB-04
H.06.01
HP UNIT FAILURE
Heat pump outdoor unit defective.
H.06.02
HP HYDRAU BACKUP LOCKING PCU hydraulic back-up blocked
H.06.04
HP PCU COM EREOR
Loss of communication with PCU
When one of the failure codes below is displayed, contact the professional
responsible for maintenance of the hybrid heat pump.
Tab.29 List of failure codes
Code
Message
Description
E.02.13
BLOCKING INPUT
Input lock BL
8 Troubleshooting
46