6.1.4 PCB parameters SCB-04
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.22 List of parameters accessible to the user
Parameters
Description
Factory setting
Customer setting
AP073
SUMMER / WINTER set point switch:
Can be set from 15 to 30°C
Set to 30.5°C = function deactivated
22°C
AP074
SUMMER override:
0 = OFF
1 = ON
0
CP010
Heating water flow temperature set point for the area heated
Can be set from 7 to 100°C.
40°C
CP040
Post-operation time of the generator pump
Can be set from 0 to 20 minutes
4 minutes
CP071
Room temperature set point in reduced mode
Can be set from 5 to 30°C.
16°C
CP072
Room temperature set point in comfort mode
Can be set from 5 to 30°C.
20°C
CP320
Circuit operating mode
0 = Timer program
1 = Manual
2 = Frost protection
0
CP350
Not available on this version
CP360
Not available on this version
CP540
Swimming pool water temperature set point
Can be set from 0 to 39°C
Set to 0: frost protection operation
20°C
CP570
Not available on this version
6.1.5 COUNTERS / TIME PROG / CLOCK menus / PROG COOL
This menu contains the following sub-menus:
COUNTERS
TIME PROG : timer program
CLOCK
PROG COOL
Sub-menu COUNTERS
Tab.23 List of parameters
Parameters
Description
Unit
PCB
EHC-02
PCB
SBC-04
AC001
Number of hours' operation
hours
x
x
AC002
Number of hours' compressor operation since the last service hours
x
AC003
Number of hours' operation since the last service
hours
x
AC004
Number of hours' compressor start-up since the last service
hours
x
AC005
Consumption in heating mode
kWh
x
AC006
Consumption in domestic hot water mode
kWh
x
AC007
Consumption in cooling mode
kWh
x
AC008
Energy recovered in heating mode
kWh
x
AC009
Energy recovered in domestic hot water mode
kWh
x
6 Settings
7611444 - v02 - 11122015
35