![Dedicated Micros DV-IP NV8 Скачать руководство пользователя страница 125](http://html1.mh-extra.com/html/dedicated-micros/dv-ip-nv8/dv-ip-nv8_installation-manual_2462360125.webp)
125
NV1
Installation Guide
125
Zone Inputs
This menu allows the configuration of established alarm zones. A single or multiple trigger can be
used to generate an alarm. It is possible to allocate up to 32 alarm zones to carry out a combination
of actions. Use these options in conjunction with the Zone Actions menu.
Entry time
This is the number of seconds allowed for the user to enter the
zone and disable the alarms. If the alarm is not disabled within
this period the alarm will be triggered..
Exit time
This is the number of seconds from the alarm being set within
which the user must exit the set zone. If the user is still within the
zone after this time period the alarm will be triggered.
Zone
An alarm zone can be established to logically groups alarms
and initiate actions when an alarm is activated, there are 32
configurable zones.
Title
This information is stored along with the relevant images in the
database, ensure this has relevance to the alarm zone.
Pre Alarm sec.
This is the time period prior to the start of the alarm included
with the alarm recording for archive. These images will also be
protected from being overwritten.
Note: It is recommended that the Pre-Alarm option be set to the same value as the Pre-Trigger
setting in the “Profile Record“ menu. This will ensure successful playback of high quality
Pre-Trigger images. High quality pre-trigger images will only playback properly if review
(playback) starts prior to the pre-trigger initiation.