![Dedicated Micros DV-IP HD Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/dedicated-micros/dv-ip-hd/dv-ip-hd_installation-and-operation-manual_2462363016.webp)
draft
Dedicated Micros ©2008
1
D
V-IP HD
End Of Line Circuitry
The following describes the EOL tamper alarms circuitry needed when EOL has been configured.
There should be two resistive values within the tamper alarm circuitry. These must be located inside
the alarm device (furthest point from the unit).
The alarm state could be Normally Open or Normally Closed, however the tamper states are the
same for both settings.
Open, the resistive value is 6.8K ohms (1K + 5.6K).
Closed, the resistive value is 1K ohms, as the circuit does not see the 5.6K ohm resistor.
Open Circuit Tamper, the resistive value is infinity as the circuit has been cut and therefore is ‘open’.
Short Circuit Tamper, the resistive value is 0 ohms.