Dedicated Micros ©2010
78
CamV
u 2000
Draft
Video server port
This field allows the RVRC to connect to the unit through a router that
is using port forwarding e.g. if the video server does not appear on
port 80 (HTTP), to the external network. Enter the port number used
for forwarding here if required.
Alarm server ref. ID
This is the reference name/ID that will be presented to the RVRC
viewing application. It should therefore have some significance to the
Operator.
Remote alarm reporting
This must be enabled for the unit to automatically connect
on alarm.
Remote camfail reporting
Enabling this option ensures the unit reports camera failure on any of
the inputs to the RVRC.
Remote Startup Reporting
This will send an alarm report when the unit starts up. Any system
resets will be identified.
ARC Ping Enabled
Should the modem/router at the Alarm Receiving Centre be dormant, the
unit will ‘Ping’ the ARC prior to sending reporting data.
Alarm responder port
This specifies the network port number used for reporting to the alarm
server. In normal circumstances this should be left at the default value
(23).
Dial retry time (secs)
If the initial connection attempt fails, the unit will wait for the specified
time period (in seconds) before attempting to re-connect.
Dial count
This identifies the number of times the unit will attempt to connect
after a failed attempt. A setting of ‘0’ means no limit and the unit will
continue to try and connect until successful.
Zone Act (Green)
Opens the Alarm Settings -> Zone Actions page.
Network (Yellow)
Opens the Network Settings -> Network page.
Email (Blue)
Opens the Network Settings -> Email page.
Refresh (Purple)
Refreshes the current page
Содержание CamVu 2000
Страница 1: ...CamVu 2000 Installation and Operation Manual ...
Страница 108: ...Dedicated Micros 2010 108 CamVu 2000 draft ...
Страница 109: ...Dedicated Micros 2010 109 CamVu 2000 draft ...