Inputs
This menu allows configuration of the alarm settings, refer to ‘Installing the Unit’ for hardware
installation guidance.
Number
This identifies which input is being configured. The unit supports 2
on-board alarms.
Enabled
Each input must be enabled to function. If the input is not enabled and
an alarm is received, the unit will not acknowledge the alarm.
N_O (Normally Open Contact) N_O indicates the non-alarm state of the input. Tick the N_O
checkbox to set the corresponding input to Normally Open. The alarm
will then trigger when the input is closed (shorted). If left as Normally
Closed (the default setting), the alarm will trigger when the input is
opened.
Note:
If EOL alarms are to be used, this option should not be selected i.e. leave set as
Normally Closed.
Pulse Ext (s)
A pulse extension is used to prevent double triggers on a single
alarm. The pulse extension time starts on an alarm trigger. If that
contact is triggered again after the first alarm has finished but within
the pulse extension, the second trigger will not restart the alarm, but
will extend the current alarm duration. Enter the time in
seconds
for this extension.