background image

13

6.4  RATE OF OIL RETURN TO FRYER SLOWS?

Rate of oil

return to the fryer

is slowing.

Is this the

first fryer to be filtered

during this filtering

session?

Check the filter

paper in the filter

pan.

Is the filter

paper properly secured

by the hold down

ring?

Paper may be

plugged by improper

use of precoat/slurry.

Paper may not be

secured by the hold down

ring.  Air is being allowed

to get into the system.

Change the filter paper.

 Throw away the old top

sheet and use the old

bottom sheet as the new top

sheet.

Take a new sheet and

place it in the bottom

of the pan.  Place the
new top sheet over it.

Secure the filter

papers by latching

the hold down ring.

Pour slurry over new filter

papers.

Check the filter sump.

 Sediment collects

around the suction pipe

in the filter bottom.

Remove the filter

pan cover.

Unlatch hold-down ring and

remove the filter paper and

filter paper support grid.

Clean support grid

and set aside

temporarily.

Wipe sediments

out of the bottom

of the filter pan.

Inspect drain ports at the

bottom rear of the filter pan

and remove any sediment

or visible blockages.

Reassemble the filter

pan assembly.  Turn

the pump motor "ON".

Has

the oil return rate

improved?

Conduct normal

filter operations.

Blockage may be

between the filter pan

 bottom and the flex

 hose valve.

Go to flowchart titled

"Blockage between

Filter Pan and Flex Hose

Valve" on page 14.

Yes

No

Yes

No

Yes

No

Содержание 75SCF

Страница 1: ...ial Food Equipment Service Association recommends using CFESA Certified Technicians Price 6 00 24 Hour Service Hotline 1 800 551 8633 819 5658 10 98 Super Cascade Filtration Systems Installation Opera...

Страница 2: ...84 OR LATEST EDITIONS CAUTION INSTRUCTIONS TO BE FOLLOWED IN CASE THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONTACTING THE LOCAL GAS COMPANY OR...

Страница 3: ...y The factory address and phone number are on the cover of this manual To speed up your order the following information is required Model Number Type Serial Number With Without Heater Optional Equipme...

Страница 4: ...ts This data is essential when contacting the factory about a unit or ordering special parts 2 5 PRE INSTALLATION a GENERAL These filters when used in combination with a fryer require no additional sp...

Страница 5: ...y b First place the support grid in the bottom of filter pan c Put two filter paper sheets on top of the support grid Be sure the paper covers the whole filter pan bottom d Position the hold down ring...

Страница 6: ...er into oil in the fry vessel Do not sprinkle Magnasol powder in the filter unit as this will clog the oil intake in the filter pan bottom c Place filter pan cover onto the filter pan assembly d Roll...

Страница 7: ...r a Measuring Cup Used to measure sixteen 16 ounces by volume of filter powder b One gallon aluminum pitcher or bucket For dumping oil into fryer to flush out debris c Gloves Used to expedite filterin...

Страница 8: ...iness and scrub if necessary Ensure there is no build up of shortening around the nipple assembly e Check the filter pan for cleanliness and scrub if necessary check the drain ports at the bottom rear...

Страница 9: ...If equipped with a optional heater before filtering turn the filter switch to the heater HTR position for a few minutes in order to melt the solid shortening in the pump WARNING THE OIL TEMPERATURE OF...

Страница 10: ...nto the fryer i Turn filter switch on the fryer to the OFF position after all the oil has been pumped back into the fryer Allow the pump to run for 10 13 seconds after air bubbles appear in the fryer...

Страница 11: ...is should clear the filter lines of any remaining oil or shortening b Remove the filter unit from the fryer Scrape the top piece of filter paper Replace filter paper if it is scuffed or dark c Remove...

Страница 12: ...s into the fryer through the flexible hose for about ten seconds If it is blowing bubbles air is moving through the lines and they cannot be plugged b When filtering is completed always disconnect the...

Страница 13: ...sure it is cool before handling Try blowing air through it Can you blow air through it Submerge hose into hot water over 120 degrees F Keep both ends out of the water If water gets into the hose the...

Страница 14: ...r it Secure the filter papers by latching the hold down ring Pour slurry over new filter papers Check the filter sump Sediment collects around the suction pipe in the filter bottom Remove the filter p...

Страница 15: ...n Pump is clear of any blockages Go to page 11 and continue following the flowchart Pump motor is clogged or faulty Contact your local Factory Authorized Service Center Check filter circuit breaker Pu...

Страница 16: ...h filter medium configurations are shown above Filter Paper and Magnum Filter Leaf assemblies The Magnum Filter Leaf system is used in certain models of the 2424 SCF only All other Super Cascade Filte...

Страница 17: ...23 H os e As s e m bl y w F it t ings 44764 Super Cascade Filter Assembly 55395 I t e m No De s cript ion Par tNum be r NotSh ow n Fil t e r Crum b Bas k e tAs s e m bl y 4479 0 NotSh ow n SCFLDrain E...

Страница 18: ...H D Z P GR5 1004 22 Nut Nyl ock 20 1005 23 H os e As s e m bl y w F it t ings 44764 Super Cascade Filter Assembly 18UE SCF 55455 I t e m No De s cript ion Par tNum be r NotSh ow n Fil t e r Crum b Bas...

Страница 19: ...8 NPT 1414 7 El bow St re e t3 8 x 9 0 S STL 2007SS 8 Nippl e 3 8 x 5 1 2 S STL 2164SS 9 El bow St re e t3 8 x 9 0 S STL 2007SS 10 Coupl e rAs s e m bl y 3 8 NPT 55016 11 Coupl e r Nippl e 3 8 NPT 141...

Страница 20: ...ies 14501 South Broadway Gardenia California 90248 TEL 1 310 323 5000 FAX Parts 1 310 327 3343 FAX Tech Support 1 318 219 7135 Price 6 00 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 81...

Отзывы: