24G SERIES FLATBOTTOM GAS FRYERS
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-13
3.7 Gas Conversion Procedures (cont.)
NON-CE UNITS ONLY:
See gas valve illustration below for reference when performing gas valve conversions.
When converting from natural gas to propane (or vice-versa), the following procedures apply:
♦
Burner orifices and pilot orifice
MUST
be replaced (see page 3-11 for required component
part numbers).
♦
Adjust orifice gas pressure by turning the gas-valve adjustment screw (see page 3-11 for gas
types and pressures).
♦
After adjustment, replace the adjustment-screw cover.
♦
Factory
MUST
be notified so the conversion can be documented and a new rating plate can
be sent out.
Conversion from one gas family to another (i.e. changing from natural gas to propane) requires
special components. Obtain the necessary components using the tables on page 3-11.
Conversions can only be executed by qualified, factory-authorized personnel
.
Pressure flow adjustment
(remove cover screw to access)
ON/OFF Gas
Knob
Pilot gas supply
connection.
Pilot pressure
adjustment (remove
cover screw to access)
ON Button- Pilot
Gas-Flow
OFF Button
Thermocouple
Connection
Vent Tube
Connection
Pilot pressure
adjustment
Non-CE gas valve (typical)
CE gas valve (typical)