4
1.4 BaSic refrigeration toolS
The following list contains some of the tools required for basic refrigeration repairs:
Hoses with R-134a couplers (must meet standards for handling R-134a refrigerant)
1.
Approved and certified recovery system for R-134a
2.
Manifold gage set for R-134a
3.
Charging cylinder with R-134a
4.
Weight scale (preferably in ounces to the nearest tenth of an ounce)
5.
Access valves
6.
Small and large tubing cutter
7.
Brazing torch
8.
Swaging tools
9.
Multimeter
10.
Leak detection equipment for detection of R-134a
11.
Standard hand tools (assorted Phillips and standard screwdrivers, sockets, allen wrenches, adjustable wrenches, etc.)
12.
Rivet gun and assorted rivets
13.
Drill motor and assorted metal drills
14.
Vacuum pump
15.
1.5 inStallation
Unit can be installed freestanding or built-in. The front of the unit must be unobstructed for proper air circulation
•
and operation at all times.
Unit must be on a LEVEL surface capable of supporting the loaded weight of the unit.
•
1.6 electrical reqUirementS
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow these requirements could result in personal injury, electrical shock, or fire.
120 VAC, 60 Hz., single phase power is needed
•
Use an outlet with a 15 amp circuit. A ground fault circuit interrupter (GFI) electrical receptacle is to be used to supply
•
electrical power to the refrigerated drawer.
It is recommended that a single circuit receptacle be used for this unit only. DO NOT USE AN EXTENSION CORD.
•
INTrOduCTION