background image

Fastners con’t 
 
Pneumatic wheel torque locations 

All bolts holding the wheel to the structure 
must be a torque setting of 20 ft.lbs (27 
N.m). Figure 4.1.2.2.

 

 
 
 
 
3. Cable 

Tie-Backs 

Check the cable tie-backs on the structure.  
The cables must be tight to apply slight 
pressure on the unit, Figure 4.2.1.3. DO 
NOT OVERTIGHTEN. 

 

4.  Overload Detection Gusset 

 

 This gusset is an indicator of a previous fall 
or misuse/abuse.  These gussets are 
located on each end of the rail supporting 
the rail from the vertical stanchion as shown 
in Figure 4.2.1.4.  Inspect the gussets 
visually for straightness and there is no 
visible deformation or bend indicating an 
incident.  Please ensure the proper M.A.F. 
device is used for this product and read all 
labels (see Section 5) prior to use. 
 
This gusset not only provides visual 
indication of a fall or misuse but also 
provides better protection against the rest of 
the rail components from becoming 
damaged and reduces costly repairs to the 
unit. 

 

5.   Structural Components

 

Check the components for cracks, dents, 
bends, or breaks.  Minor cosmetic damage 
in the component body will not affect the 
function of the FSHRS System.  However if 
there are major dents or any other structural 
damage, the unit should be removed form 
service and returned to the manufacturer for 
service. 

 
6. Corrosion 

Check all components for damage from 
corrosion.  Although all components resist 
corrosion, working in corrosive 
environments can lead to damage.  Inspect 
all structural components and fasteners for 
signs of damage.  If corrosion damage is 
found, remove from service and return to 
the manufacturer for service. 

 
 
 

Torque Locations

 

  

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 4.1.2.2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 4.2.1.3 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 4.2.1.4 

Overload gusset assembly 

 
 

 

Содержание 8520215

Страница 1: ......

Страница 2: ......

Страница 3: ... service or other information The serial number plate is located where indicated Please mark the number in the space provided for easy reference SERIAL NUMBER LABEL Model____________________________ Serial Number_____________________ MADE IN CANADA Pt 12817 Rev 03 SERIAL No SYSTEM MODEL COMPONENT MODEL MFG DATE www capitalsafety com LOT No ...

Страница 4: ...tem This manual covers the FSHRS manufactured by Unique Concepts Keep this manual handy for frequent reference and to pass to new operators Establish a regular training program for experienced and new operators per these instructions Establish a regular maintenance and inspection program to keep the equipment in top condition Modular components are labeled with the capacities and rating to which t...

Страница 5: ...ING and CAUTION with the safety messages The appropriate signal word for each message has been selected using he following guide lines DANGER Indicates an imminently hazardous situation that if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situations or for hidden or unseen hazards WARNING Indicates a potentially hazardous situation that i...

Страница 6: ...hers to possible serious injury or death Do not modify the equipment in any way Unauthorized modification may impair the function and or safety and could affect the life of the equipment Think SAFETY Work SAFELY 2 1 GENERAL SAFETY 1 Read understand and follow the User Manual and all safety signs before using maintaining or inspecting the equipment 2 Refer to and follow applicable ANSI OSHA CE or o...

Страница 7: ...nvironmental hazards This list includes but is not limited to a Corrosion that may affect the structural integrity of the life line or other components b Chemicals which can degrade components and not be visible c Toxic gases Rescuers or workers can be killed in toxic environments d Heat or elevated temperatures e Moving machinery Workers or auxiliary equipment can be contacted by or pulled into m...

Страница 8: ... or failure to follow instructions may result in serious injury of death It is the responsibility of the owner s organization or operator to read this manual and to train all other operators before they start working with the equipment Follow all safety instructions exactly Safety is everyone s business By following recommended procedures a safe working environment is provided for the operator bys...

Страница 9: ...or lower than the lowest rated component of your system 12 Establish a regular training program for new and experienced workers 13 Establish a detailed inspection program for your equipment and document the findings Return the equipment to the manufacturer for rework if any problems are found 14 Plan your work program before starting Have the required people equipment and procedures available to d...

Страница 10: ...ea Note The SRL line must not drag or bend over a leading edge while accessing the work area To eliminate that problem reposition the unit Follow SRL manufacturer instruction carefully Step 5 IMPORTANT follow the safe working area instruction carefully If using an SRL more than 10 feet in length carefully follow the safe working area guidelines as shown Step 6 If applicable transfer tagged lifelin...

Страница 11: ...6 FT 1 8 m 6 FT 1 8 m WORKING SURFACE FULLY EXTENDED POSITION MIN 5 FT 1 5 m C 4 3a 3b 3b L SRL LIFELINE STEPS 3 4 ...

Страница 12: ...10 FT 3 m Model 20216 20 FT 6 m Model 20215 SAFE WORKING AREA 6 FT 1 8 m 6 FT 1 8 m STEP 5 TOP VIEW ...

Страница 13: ... 4 2 2 Record results and keep documentation 2 Lubricate Perform a unit lubrication interval See Section 4 1 2 3 Keep instructional and safety labels clean and legible at all times Clean or replace as required See Section 5 for label information and part numbers 4 Lubricate winch as per instructions in Winch Operator s Manual if applicable 5 Remove the equipment from service if a problem is found ...

Страница 14: ...4 1 2 Lubricants 1 Chain Lubricant Use a light lubricant like WD 40 to lubricate the chain 2 Brake and Drive Lubricant Use WD40 ...

Страница 15: ... using a mild soap and a damp cloth Replace if any are illegible Refer to Section 5 for a listing of all labels See Figure 4 2 1 1 2 Fasteners Fasteners must be checked and tightened to the specified torques in Figure 4 2 1 2 Contact your local dealer or UCL manufacturer for any replacement fasteners that may be required Bolt Size Grade Torque Setting in Grade 5 30 35 ft lbs 40 48 N m in Grade 8 3...

Страница 16: ...prior to use This gusset not only provides visual indication of a fall or misuse but also provides better protection against the rest of the rail components from becoming damaged and reduces costly repairs to the unit 5 Structural Components Check the components for cracks dents bends or breaks Minor cosmetic damage in the component body will not affect the function of the FSHRS System However if ...

Страница 17: ...ains operational parts that may include pulleys and or rollers These parts must be carefully checked for chips cracks or worn areas that can cause malfunction during operation of the system Make sure that all the adjustment points are in full functional condition This may include parts that contain pins bolts tri screws and adjusting screws There are also mechanical adjustments which may include a...

Страница 18: ......

Страница 19: ... Product Inspector Serial if Applicable Paint Labels Fasteners Secure Undamaged Corrosion Details Structural Damage Details Sign Off Equipment Identification Type Application Usage Storage Location Components Please write description below Corrective Action Taken if required Winch inspection and documentation as per Winch Manual if applicable Record Winch serial numbers and counter reading under c...

Страница 20: ......

Страница 21: ... engineer and only then a decision can be made by the rating labels as to which is the lowest rated component and if it meets or exceeds local standards Proper maintenance of the labels must be established by the operator entrant to keep system use safe If labels are damaged the operator entrant must enforce a lock out tag out procedure New labels are available from the local dealer or UCL manufac...

Страница 22: ...e proper installation and use of the equipment mentioned in this manual These specifications contain application specific ratings and mounting requirements determined through design and testing Please read and follow these specification sheets carefully to ensure the proper installation of each item ...

Страница 23: ...ia New Zealand 800 245 002 Europe Middle East Africa 33 0 497 10 00 10 Northern Europe 44 0 1928 571324 www capitalsafety com info capitalsafety com SPECIFICATIONS PAGE 1 OF 4 UCL Free Standing Horizontal Railing System c w Urethane Wheels Model 8520216 8520215 8520216 8520215 Model 8520216 8520215 ...

Страница 24: ...thane Wheels Model 8520216 8520215 ISO 9001 REGISTERED Capital Safety USA 800 328 6146 Canada 800 387 7484 Asia 65 6558 7758 Australia New Zealand 800 245 002 Europe Middle East Africa 33 0 497 10 00 10 Northern Europe 44 0 1928 571324 www capitalsafety com info capitalsafety com ...

Страница 25: ...thane Wheels Model 8520216 8520215 ISO 9001 REGISTERED Capital Safety USA 800 328 6146 Canada 800 387 7484 Asia 65 6558 7758 Australia New Zealand 800 245 002 Europe Middle East Africa 33 0 497 10 00 10 Northern Europe 44 0 1928 571324 www capitalsafety com info capitalsafety com ...

Страница 26: ...thane Wheels Model 8520216 8520215 ISO 9001 REGISTERED Capital Safety USA 800 328 6146 Canada 800 387 7484 Asia 65 6558 7758 Australia New Zealand 800 245 002 Europe Middle East Africa 33 0 497 10 00 10 Northern Europe 44 0 1928 571324 www capitalsafety com info capitalsafety com ...

Страница 27: ...Free US 800 328 6146 solutions capitalsafety com ASIA Capital Safety Group Asia Pte Ltd No 6 Tuas Avenue 18 Singapore 638 892 Phone 65 6558 7758 inquiry capitalsafety com AUSTRALIA NEW ZEALAND Capital Safety Australia Ltd 20 Fariola Street Silverwater Sydney NSW 2128 Australia Toll Free 1 800 245 002 Australia Toll Free 0800 212 505 New Zealand EUROPE MIDDLE EAST AFRICA Capital Safety Group E M E ...

Страница 28: ...sia 65 6558 7758 Australia New Zealand 800 245 002 Europe Middle East Africa 33 0 497 10 00 10 Northern Europe 44 0 1928 571324 www capitalsafety com info capitalsafety com Printed in Canada Revision Number 03 Issue Date March 21 2007 Part Number 8518732 ...

Отзывы: