4.10 Return time setting: (Fluorine cycle unit is valid; parameter 64=1)
•
Press and hold the “ ” button for 3 seconds in the main interface to enable/disable
the timed water return mode.
•
When the timed water return mode is enabled, the timed return time setting is
entered.Press“ ” to switch the start time of the two time slots in turn, the hour part, the
minute part, the hour part of the end time.
•
The corresponding parts are flashed when the corresponding value is switched. The
corresponding time period is displayed and the“ON” or“OFF” symbol is flashing.
•
Press “
∧
” or “
∨
” i.e up or down to display the corresponding value.
•
After setting the timed period, press and immediately release the “ ” button , the
changes can be saved and returned to the normal state.
•
When the timing control mode is enabled, the corresponding symbols are displayed
separately during the working period and the non-working period.
•
In the power-on state, the water is automatically returned only during the set working
period.
•
When the start time and end time of a certain working period are the same, it is
regarded as canceling the timing period.
•
When all timed periods are cancelled, it is considered to be in an untimed return time
period throughout the day.
•
If the start time of a certain working period is greater than the end time, the end time is
considered to be the next day. The factory default return water time is as follows:
A, time period 1 opening time: 6:30
B, time period 1 closing time: 7:30
C, time period 2 opening time: 18:30
D, time 2 closed time: 22:30
4.11Query running status:
•
When the main interface of the power on or off is displayed, press and hold the “
∧
” or
“
∨
” button for more than 3 seconds to enter the running status query interface. Press
and immediately release the “
∧
” or “
∨
” button to check each operating condition.
Press and immediately release the “ ” button or automatically return to the normal
display state without any button operation in 30 seconds.
•
After entering the view mode, the last viewed data code (the default is “00” after
power-on) and its corresponding value are displayed.
•
After each press and immediately release the “
∨
” button, the following status can be
displayed .
4.9 Forced sterilization
•
If the controller is in the normal display state and it is currently in the heating mode,
press the “M”+“
∧
”+“
∨
” button at the same time for more than 5 seconds to activate
or deactivate the “sterilization” function.
•
The flashes at this manual “sterilization” operation.
•
When heat pump is in cooling mode, "sterilization" operation is not allowed.