19
4.6 Set the cooling/heating mode
•
With the controller in normal display, press “ ” to switch between cooling or heating
mode.
•
When switching to the cooling or heating mode, the corresponding symbol will flash
quickly for 3 seconds and then return to the normal display state.
•
When switching to the cooling mode, the temperature judgment automatically selects
“manual mode”, and the water temperature can be set (For Domestic Hot Water - 25
- at this time).
•
When the cooling/heating mode is switched, the compressor is allowed to start
running after at least 3 minutes of stopping.
4.7 Forced speed heating
•
When the controller is in normal display state and heat pump is in the power-on state
at the same time the heat pump needs to be in the working period after the timing
control is enabled.
•
The current heating mode is met and the temperature condition for continued heating
is satisfied, No other alarms that do not allow "speed heating" occur.
•
Press“M” + “
∧
” button at the same time for more than 5 seconds, to active/deactivate
the “speed heating” function. When the “speed heating” mode is on, the symbol
lights up.
•
When the heat pump is in cooling mode, “speed heating”is not allowed.
•
The three time slots are as follows; 05:00-07:00; 16:00-18:00; and 20:00-00:00.
•
When the timing control mode is enabled, the corresponding symbols are displayed
in the working period (ON) and the non-working period (OFF) respectively.
•
In the power-on state, heating/cooling is performed only during the programmed
period, and the rest of the time , the unit is not heating/cooling.
•
When the start time and end time of a certain working period are the same, it cancels
out the scheduled period.
•
When all timed periods are cancelled, the unit considered to be working throughout
the day.
•
If the start time of a certain working period is greater than the end time, the end time is
considered to be the next day.
4.8 Forced defrosting
•
When the controller is in normal display state and heat pump is in the power-on state.
heat pump needs to be in the working period after the timing control is enabled.
•
The current heating mode is set and the defrosting time set above zero and the
temperature condition of the defrosting is continued, No other alarms that do not
allow "frost" occur.
•
Press“M” + “
∨
” button at the same time for more than 5 seconds to activate or
deactivate the "Defrost" function. The symbol is illuminated when the "Defrost" is
running. If heat pump is in cooling mode, "defrosting" operation is not allowed
.