10
Leakage Protection
Ground Wire
Manual Switch
P
ower Supply
Leakage Protection
Device
Fig 10: Power Protection
Model
HPW200/300
Power
Supply
Min. Cable diameter
(mm2)
Manual Switch
(A)
Leakage
Protection
Device
220V/50Hz
>2.5
Size
(continous
length
<30m)
Ground
Wire
Capacity
Fuse
>ø1.0mm
>20
20
Below 30mA
0.1 sec
Directly connect power supply wire with hplug when using the
heat pump
NOTE
The external power supply box must be installed with
protection.
WARNING