background image

PUMP DATA

2

Enclosure Class: 

IPX8            

Insulation Class: 

F            

Voltage:

1x240V              

Speed: 

2900rpm

OPERATING CONDITIONS

Pumped  liquid: 

Thin,  clean,  chemically  non-aggressive  liquid  containing 

some particles and fibres

0

Max fluid temperature: 

+35 C

Max Operating Depth:

 7m

Model

Motor

Dimensions (mm)

Weight 

(kg)

kW

Outlet

(”)

W

DDW 400S

DDW 750S

0.4

1.7

370

5

5

6

35

0.75

3.1

220

1

4.2

7

7

H

Current (A)

DDW 750V

DDW 1000V

Max. Particle

size (mm)

385

Min 400

Min 350x350

H

W

1. Carrying handle
2. Float switch height adjustment
3.Hose  adapter  for  pressure 

connection

4. Float Switch
5. Pump casing
6. Mains cable and plug

2

4

6

5

3

1

Содержание DDW 400S

Страница 1: ...DDW DOMESTIC PUMPS Installation Operating Manual DDW400 750S DDW750 1000V...

Страница 2: ......

Страница 3: ...SPECIFICATIONS 1 1 2 WARNINGS AND SYMBOLS 3 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted 3 INSTALLATION 4 4 ELECTRICAL CONNECTIONS 4 5 MAINTENANCE 5 6 TROUBLE SHOOTING 6 7 WARRANT...

Страница 4: ...suitable for threaded or hose connection MOTORS Pumps are provided with integral non overloading induction motors designed for continuous operation A thermal cut out is provided in the motor winding t...

Страница 5: ...0 Max fluid temperature 35 C Max Operating Depth 7m Model Motor Dimensions mm Weight kg kW Outlet W DDW 400S DDW 750S 0 4 1 7 370 5 5 6 35 0 75 3 1 220 1 4 2 7 7 H Current A DDW 750V DDW 1000V Max Pa...

Страница 6: ...onds where they may be people using the water WARNING WARNING WARNING WARNING WARNING Repairs must be carried out only by a qualified electrician 2 WARNINGS AND SYMBOLS WARNING WARNING Do not use the...

Страница 7: ...may be straightened as desired The pump should not be suspended by its cable or delivery pipe It should either rest on a solid level base or be suspended by steel cable or chain The pump must be conne...

Страница 8: ...r windings 5 MAINTENANCE The pump requires no routine maintenance and if correctly installed should give long term trouble free service However the following should be noted If pump performance drops...

Страница 9: ...ed C l e a n s u c t i o n s e e maintenance section Delivery hose obstructed Check delivery hose rectify Pump runs with no flow Pump suction obstructed Check suction Delivery head too high Reduce del...

Страница 10: ...any warranty condition or liability implied by law the liability of Davis Shirtliff hereafter called the Company in respect of any defect or failure of equipment supplied is limited to making good by...

Страница 11: ......

Страница 12: ...INS181C 08 18 www davisandshirtliff com...

Отзывы: